REMOTE CONTROL: DEVICE DEPENDENT COMMANDS
Page 81
:harmonic2 < choice >
:offset <numeric value> [dB]
:longitudinal :level <numeric value> [Vrms]
:Noise:Distribution <D4Mode|D2Mode>
:load1 <boolean>
:load2 <boolean>
:output <boolean>
:quiet
9.2.2
Crosstalk Generator A
9.2.2.1 XTalk Generator A – Type
:source?:xtalkA :type <choice>
Range: OFF
T1.601
DSLNEXT
HDSL
HDSL+ADSL
9.2.2.2 Xtalk Generator A – Level
:source?:xtalkA :level <numeric value> [dBm]
Range: –75.0 to –30.0 dBm in
0.1 dB steps
9.2.2.3 Xtalk Generator A – Program
:sourceA:xtalkA:Program:Data
:Start
tells the system to start a new data set
:Name
must be in quotes, and is a maximum of 16
characters. (Type will, by default, be ‘external’
unless a name is programmed)
:Minimum and Maximum
as per your level range
Summary of Contents for DLS 400A
Page 1: ...Revision 0 21 September 1999 TestW rks Operating Manual DLS 400A H N HN Wireline Simulator ...
Page 2: ......
Page 12: ......
Page 63: ...ADSL NOISE GENERATOR DESCRIPTION Page 51 Figure 6 5 Cook Pulse Figure 6 6 ADSL Impulse c1 ...
Page 206: ......
Page 224: ......