9024-065-G-11-14
22
OFF
RESET
ALARM
MANUAL RELEASE
2.2 Setting Input Power Jumper and Turning Power ON
There is a
“IN POWER/BATT”
jumper on the circuit board that
MUST
be set correctly or the operator could get damaged.
Considerations should be made when connecting loop detectors (specifically, the automatic exit loop), radio receiver and any
safety devices to a solar powered gate operator. These devices will constantly drain the operator’s power. Since the operator has
a limited power source (batteries), considerations should be made before installing these devices.
The pins
MUST
be
jumpered together
when using Solar
power.
1234567
8
ON
12345678
ON
1 2 3 4 5 6 7 8 9 10
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
EXIT
LOOP
REVERSE
LOOP
IN POWER/BATT
PWR
SEL
REV SENSE
P3
SELF TEST
RESET
RED=CHARGING
GREEN=CHARGED
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF
ON
POWER
P4
P2
1
6
TIME DELAY
12345678
ON
12345678
ON
1 2 3 4 5 6 7 8 9 10
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
EXIT
LOOP
REVERSE
LOOP
IN POWER/BATT
PWR
SEL
REV SENSE
P3
SELF TEST
RESET
RED=CHARGING
GREEN=CHARGED
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF
ON
POWER
P4
P2
1
6
TIME DELAY
PWR
SEL
IN POWER/BA
TT
DO NOT
cycle the operator until the “
DIP-Switches”
and the “
Limit Switches”
have been adjusted.
Damage could occur to the gate and gate operator.
See pages 26, 27 and 28.
DC Power
Switch
KEY
SWITCH
Battery Charging
LED Monitor
OFF
ON
To power up operator
:
turn DC power
switch
ON
. Press
KEY SWITCH
and
LEDs will light up on circuit board.
Important Battery Plug Note:
Battery Plug P2 comes from
the factory unplugged and
needs to be plugged into
circuit board when operator
is ready to be powered up.
Loop Detectors:
DoorKing’s
plug-in loop detectors are
specifically designed to be
connected to a solar
powered gate operator. If
using a third party external
loop detector, it MUST be a
low current draw type.
Radio Receiver:
DoorKing’s 3-wire radio receiver is
specifically designed to be connected to a solar powered
gate operator. If using a third party radio receiver, it MUST
be a low current draw radio receiver type.
Safety Device Connections:
All safety devices (photo sensors and
reversing edges) MUST have a separate power source when using
solar power.
Secondary Gate Operator Connection:
NOT
available when using solar power.
24 V Maglock Connection:
NOT
available when using solar power.
This may be red when
first powering up
operator depending on
how much of a charge
the batteries have.
Battery Plug P2
2.3 Solar Power Limitations
RED=CHARGING
GREEN=CHARGED
RED=CHARGING
GREEN=CHARGED
SECTION 2 - SOLAR POWER ONLY! MODEL 9024-081
Power is limited to 250 mamps.
3-Pin Remote Terminal
1
2
3
Summary of Contents for 9024