Starting the boiler and setting the operating parameters
8
When the boiler temperature rises to the level specified by the "dt" parameter, the
controller switches to HEATING mode.
After finishing the settings and double-pressing of , you will be taken to the main
screen.
After reaching the required temperature, the controller will switch to the
MAINTAINING mode, until the temperature drops below the hysteresis – to find out
more, see
Operating parameters - HYSTERESIS
.
When you press the or button, the SETT symbol will show to inform about the
currently set temperature. Set the required value, using the same buttons: to
increase the setting or to reduce it.
Setting the parameters of the boiler
1.
Open the ash pit door.
2.
Start the feeder manually (see
Manual operation - Testing outputs
) and wait
until coal shows at the level of the blow holes.
3.
Turn off the feeder and then ignite the coal in the furnace chamber.
4.
After obtaining a stable flame, start automatic operation of the controller by
holding down for three seconds the , the display shows START, the controller
will start regular dosing fuel and will control the fan in order to obtain the desired
temperature in the boiler.
7