Operating parameters - HEATING - blowing power
This parameter allows you to set the maximum power at which the fan will operate
during HEATING mode. Change range: from 1 % to 100 % of maximum fan power, set
in the maintenance menu - see
Adjusting the maximum fan power
.
Pressing again takes you to the next setting.
In the case of the piston feeder the scope and factory setting is changed. Change
range: from 10 s to 900 s.
14
Operating parameters - FAN - run-out
This parameter allows you to set the time (in seconds) of earlier switching on of the
fan relative to the switching on of the feeder.
Pressing again takes you to the next setting.
Operating parameters - FAN - delayed switch-off of the fan
This parameter allows you to set the time (in seconds) to delay the switching off of the
fan until the feeder is switched off.
Pressing again takes you to the next setting.