Pressing again takes you to the next setting.
Central heating pump - break time
This parameter specifies the time interval in the operation of the CH PUMP (calculated
in minutes) when interoperability with the room thermostat. Change range: from 5 min
to 60 min.
Shutting down the boiler
12
When the boiler is operating in HEATING or MAINTAINING mode, you can switch it to
the DAMPING mode - during which the fan and the feeder is not working.
DAMPING mode
The boiler may be shut down due to lack of fuel, the completion of the damping
process or manually switching to the STOP mode.
When there is no fuel, EMPTY BUNK will be displayed.
11
Central heating pump - operation time
A parameter that specifies the CH pump operation time (calculated in seconds) when
interoperability with the room thermostat. Change range: from 0 s to 240 s.