background image

Fog machine H-2VSD  
 

11 / 19

 

4.1.2.

 

DMX Table 

If the device is controlled with a DMX signal, the display shows the set DMX 

address.  

 

 

 
 
 
 

Summary of Contents for H-2VSD

Page 1: ...Fog machine H 2VSD USER MANUAL ...

Page 2: ...evice on solid ground Place the device on a solid surface to avoid vibrations Do not use chemical agents for cleaning Use a clean dry cloth to remove dust Metal parts can be cleaned with a slightly damp cloth Before cleaning the device always pull out the mains plug If the device does not work properly If problems arise unplug the power cord The user should not attempt to service the device on the...

Page 3: ...bjects or surfaces must not be touched by the housing Make sure that when assembling and dismantling the device the area below the assembly site is cordoned off This also applies to the performance of service work Familiarize yourself with the functions of the device before putting it into operation Do not allow the device to be operated by persons who have no experience in it The most common caus...

Page 4: ...the device must be constructed and dimensioned in such a way that they can carry ten times the payload for one hour without causing permanent damaging deformation The installation must always be carried out with the help of a second independent suspension This can for example be a suitable safety net The secondary suspension must be designed and installed in such a way that in the event of a failu...

Page 5: ...s if they fall If you have doubts about the safety of a possible form of installation then do NOT install the device Before mounting the device ensure that the mounting surface is capable of supporting at least ten times the point load of the device s own weight Mount the device with the mounting bracket on a truss system using suitable lifting gear When installing overhead ensure that the device ...

Page 6: ...are suitable for this 2 1 3 DMX connection with terminator For installations where the DMX signal has to bridge a large distance or where the device is to be operated in an environment with increased electromagnetic radiation such as a discotheque we recommend using a DMX terminator This prevents the digital control signal from being corrupted by electrical noise The DMX terminator is simply an XL...

Page 7: ... LED dual output super jet fog machine This device has been specially developed for professional use With the unique patented Super Jet technology the strength of the output is comparable to that of Co2 jets 3 1 Features Dual output for powerful fog output Patented Super Jet Technology Stable and durable NO FLUID protection Patented Immediate Stop Technology Built in control LCD 37x 8W RGBA LEDs 3...

Page 8: ...Fog machine H 2VSD 8 19 3 3 Product description ...

Page 9: ...ays enough fluid in the tank 3 Connect the device to the mains 4 The device starts to heat up This process takes 9 minutes during which time the display shows Warming up 5 The heating process is complete Ready TO Fog appears on the display 4 1 Control It is operated via the display or via DMX MENU Calling up the menu structure to make individual settings UP TIMER Select a menu item or increase a v...

Page 10: ...Fog machine H 2VSD 10 19 4 1 1 Menu ...

Page 11: ...Fog machine H 2VSD 11 19 4 1 2 DMX Table If the device is controlled with a DMX signal the display shows the set DMX address ...

Page 12: ...r pumping fluid the pump switches off automatically and draws attention to the problem with a warning message on the display 4 1 5 Zurücksetzen der NO FLUID Warnung After the machine initiated the NO FLUID protection function after refilling the fluid there are three ways to reset the warning Hold down the Enter key until the pump is again supplied with fluid In this case the machine starts to emi...

Page 13: ...r LEDs 30 pieces Total power of the inner LEDs 56 w Total power of the outer LEDs 240W tank volume 3 5 liters range with one filling Approximately 10 minutes output volume 2209 m min discharge height 12m fluid consumption 400ml min Maximum Ejection Duration 10 sec Continuous fog output Horizontal orientation YES Inclined Orientation YES ensure no fluid leaks Vertical Alignment YES upside down YES ...

Page 14: ...chine H 2VSD 14 19 remote control NO frequency of the remote control current in P con XLR in out 3 pin 5 pin Dimensions 610x315x325mm shipping dimensions 670x410x425mm net weight 27 5kg shipping weight 29 5kg ...

Page 15: ...ntenance work Make sure the machine is installed on a structure designed for the weight 6 1 Tank Inversion To prevent fluid from leaking out the tank must be turned before the upside down assembly Loosen the screws of the tank bracket Turn the tank holder and screw it back to the housing with the previously loosened screws ...

Page 16: ...Fog machine H 2VSD 16 19 Notes ...

Page 17: ...Fog machine H 2VSD 17 19 Notes ...

Page 18: ...Fog machine H 2VSD 18 19 ...

Page 19: ...Fog machine H 2VSD 19 19 B K LUMITEC 2 rue Alfred Kastler Zone Industrielle 67850 Herrlisheim France 33 0 3 88 96 80 90 33 0 3 88 96 48 46 hello bklumitec com www bklumitec com ...

Reviews: