226
For
ARTROMOT®-SP3
devices with serial
numbers > #25.000.
The
ARTROMOT®-SP3
device is subject
to particular precautions regarding electro -
magnetic compatibility (EMC). The device
must be installed and put into service strictly
in compliance with the EMC directives set
forth in the accompanying documents.
Portable and mobile RF communication
systems may affect the
ARTROMOT®-SP3
.
The
ARTROMOT®-SP3
should not be used
adjacent to or stacked with other equipment.
If adjacent or stacked use is necessary,
ARTROMOT®-SP3
should be observed to
verify normal operation in the configuration
in which it will be used.
If you detect damage or malfunctions that
may impair the safety of the patient or
of the operator, have the device repaired
before using it.
If it is necessary to replace assemblies or
cables, only the manufacturer‘s original
parts must be used to ensure continued
compliance with EMC requirements after
repair. This requirement applies to the
power supply unit, cables and cable lengths,
drive unit consisting of the motor and the
control system, the programming unit incl.
the coiled cable and the connector.
Regarding the electromagnetic compatibi-
lity, there is no maintenance work required
during the expected service life of the
product.
The product designation
ARTROMOT®-SP3
used in the text below includes all product
variants.
12. IEC 60601-1-2 and IEC 60601-1-11
m
WARNING!
Use of accessories, transducers and cables other than those specified or provided by the
manufacturer of this equipment could result in increased electromagnetic emissions or
decreased electromagnetic immunity of this equipment and result in improper operation.
Guidance and Manufacturer’s Declaration – Electromagnetic Emissions
ARTROMOT®-SP3
is intended for use in the electromagnetic environment specified below.
It is the responsibility of the customer or user to ensure that the
ARTROMOT®-SP3
unit is
used in such an environment.
Emissions test
Compliance
Electromagnetic environment –
guidance
RF emissions to CISPR 11
Group 1
ARTROMOT®-SP3
uses RF energy
only for its internal function.
Therefore, its RF emissions are very
low and are not likely to cause any
interference in nearby electronic
equipment.
RF emissions to CISPR 11
Class B
ARTROMOT®-SP3
is suitable for use
in all establishments, including do-
mestic and those directly connected
to the public low-voltage power
supply network that supplies buil-
dings used for domestic purposes.
Harmonic emissions to
IEC 61000-3-2
complies with class
A requirements
Voltage fluctuations/flicker
emissions to IEC 61 000-3-3
complies
12.1 Electromagnetic emissions
Summary of Contents for 80.00.035
Page 234: ...230 Notes ...
Page 237: ...VII Notes ...