FloTech FT555 Automatic Truck Overfill System Tester
Page 14
10784PA Rev G
FT555 Truck Tester
Auto Test Ground Continuity System
1.
Press and release GO button to select either Ground Bolt or
Continuity. Once the selection has been made, press TEST
SELECT to move to the next screen. See step 2 for
Continuity or step 3 for Ground Bolt.
2.
Continuity
If you selected Continuity, the screen below will be shown.
Press and release the GO button to Enable or Disable the
Auto Test function. Press and release the TEST SELECT
button to move to the Automatic Test Screen. See
Performing Automatic Test Function on page 18
3.
Config Ground Test
Enable GroundBolt
GO = Change
TEST SELECT = Done
AutoTest Continuity
Enable Continuity
GO = Change
TEST SELECT = Done