![Dixie DN504P Technical Manual Download Page 5](http://html1.mh-extra.com/html/dixie/dn504p/dn504p_technical-manual_2511120005.webp)
Page 5 of 100
The Dixie-Narco P Series vender is designed
utilizing the latest technology.
UNPACKING THE VENDERS
Remove the stretch wrap and top cover from the
vender. Product cards are installed in the select
buttons.
DO NOT STORE THE VENDER
OUTSIDE WITH THE STRETCH
WRAP ON. THIS COULD CAUSE
THE STRETCH WRAP TO BOND
TO THE VENDER’S SURFACE,
WHICH COULD DAMAGE THE
FINISH.
Remove the shipping boards from the bottom of the
vender. The shipping boards are attached by the
leveling legs. To avoid unnecessary damage to the
leveling legs or base, remove the shipping boards by
using a 1½” “socket type” wrench to unscrew the
leveling legs. Be sure to replace the legs after
removing the shipping boards.
WARNING
TO AVOID THE POSSIBILITY OF A
FIRE HAZARD, DO NOT STORE
ANYTHING OR ALLOW DEBRIS OF
ANY KIND TO ACCUMULATE IN
THE BOTTOM OF THE DOOR, IN
AND AROUND THE
REFRIGERATION COMPARTMENT
OF THE CABINET, OR IN FRONT
OF THE EVAPORATOR AND
CONDENSER COILS.
WARNING: ENSURE THAT
POWER IS DISCONNECTED
FROM THE VENDER OR
THAT THE POWER
INTERRUPT SWITCH IS NOT
DEFEATED BEFORE
INSPECTING OR REPLACING
THE LAMPS, OTHER
ELECTRICAL COMPONENTS,
OR WORKING WITH OR
ADJUSTING THE VENDING
MECHANISM. FAILURE TO
COMPLY WITH THESE
INSTRUCTIONS MAY SUBJECT
THE USER TO THE RISK OF
ELECTRICAL SHOCK OR
MECHANICAL INJURY, WHICH
CAN BE SERIOUS OR FATAL.
ELECTRIC POWER NEEDED
Refer to the cabinet serial number plate to determine
the proper voltage and frequency the machine
requires (domestically this requirement is 120 Volts,
60 Hertz). The cabinet serial plate also indicates the
Amperage of the vender. The vender must be
plugged into a properly rated, single phase
alternating current outlet with its own circuit
protection (fuse / circuit breaker).
DO NOT USE AN EXTENSION CORD.
POWER SUPPLY CORD and
GROUNDING REQUIREMENTS
In accordance with the National Electrical Code and
Underwriters Laboratories Inc., beginning April 10,
2006 all domestic vending machines are equipped
with a three-wire power supply cord and Ground
Fault Circuit Interrupter (GFCI). The GFCI device
is provided as part of the power supply cord and is
either incorporated directly into the plug or mounted
on the cord adjacent to the plug.
WARNING
•
The GFCI protects against current
leakage caused by ground faults.
The GFCI is not designed to
protect against over current or
short circuits.
•
DO NOT
use the TEST and
RESET buttons on the GFCI as an
ON/OFF switch.
•
The vending machine supply cord
MUST
be plugged directly into a
properly grounded, 3 wire
receptacle that is properly
protected by a fuse or circuit
breaker. If the receptacle will not
accept the power cord plug, it must
be replaced with a properly
grounded, 3 wire receptacle in
accordance with the National
Electrical Code and Local Codes
and Ordinances. The work should
be done by a qualified electrician.
DO NOT USE A 3 WIRE TO 2
WIRE ADAPTOR
Summary of Contents for DN504P
Page 50: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 50 of 100 CAN T READ THE DISPLAY...
Page 51: ...PARTS LIST P SERIES Page 51 of 100 Chameleon 6 Select 7 Column...
Page 52: ...PARTS LIST P SERIES Page 52 of 100 LMV 8 Select 7 Column...
Page 68: ...PARTS LIST P SERIES Page 68 of 100 SELECT PANEL LMV 9 10 6 4 3 2 1...
Page 69: ...PARTS LIST P SERIES Page 69 of 100 SELECT PANEL CHAMELEON 1 4 8 3 6 7 5 5...
Page 76: ...PARTS LIST P SERIES Page 76 of 100 INNER DOOR ALL 7 3 8 1 A2 4 6 10 9 2 5 12...
Page 78: ...PARTS LIST P SERIES Page 78 of 100 HARNESSING Single Board Controller 3 9 5 6 2...
Page 80: ...PARTS LIST P SERIES Page 80 of 100 POWER DISTRIBUTION 7 11 9 10 5 3 4 2 14 8 1 17 19 18 20...
Page 88: ...PARTS LIST P SERIES Page 88 of 100 CHUTE ASSEMBLY 4 6 5 11 8 1 10...
Page 96: ...PARTS LIST P SERIES Page 96 of 100 SCREWS NUTS...
Page 98: ...PARTS LIST P SERIES Page 98 of 100 WASHERS BOLTS MISC HARDWARE...