PROGRAMMING P
SERIES
Page 10 of 100
"CHAR"
- Changer
Summary
Errors
Press select button 4 and the display will show one of the following:
-
"CC"
, indicating a changer communication error. (No communication for more than 2
seconds)
-
"TS"
, indicating a tube sensor error.
-
"IC"
, indicating an inlet chute blocked error (no coins sensed in acceptor for 96 hours).
-
"TJ##"
, indicating a tube jam error.
-
"CRCH"
, indicating a changer ROM check sum error (failed changer).
-
"EE"
, indicating excessive escrow attempts (more than 255 since last coin sensed).
-
"NJ"
, indicating a coin jam reported by coin mech.
-
"LA"
, indicating a low coin acceptance rate (less than 80%).
-
"DIS"
, indicating an acceptor is unplugged.
-
"ROUT"
, indicating a coin was misrouted.
Press select button 1 will return to
"CHAR"
if all changer errors have not been cleared.
If all changer errors have been cleared the next error code will be displayed or
"NONE"
if there are
no errors.
Press select button 1 will return to
"EROR"
.
"BUAL"
-
Bill Validator Summary Errors
Press select button 4 and the display will show one of the following:
-
"BC"
, indicating a bill validator communication error. (No communication for more than 5
seconds)
-
"BFUL"
, indicating the bill stacker is full.
-
"BILL"
, indicating a defective motor in the validator.
-
"BJ"
, indicating a bill jam in the validator.
-
"BRCH"
, indicating a check sum error.
-
"BOPN"
, indicating an open stacker.
-
"BS"
, indicating a bill validator sensor error.
Press select button 1 will return to
"BUAL"
if all changer errors have not been cleared.
If all validator errors have been cleared the next error code will be displayed or
"NONE"
if there are
no errors.
Press select button 1 will return to
"EROR"
.
"CRDR"
-
Card Reader Summary Errors
Press select button 4 and the display will show one of the following:
-
"CRC"
, indicating no card reader communication for 5 seconds.
-
"CRXY"
, indicating the most recent "non-transient error" from the card reader (failed card
reader).
Press select button 1 will return to
"CRDR"
if all changer errors have not been cleared.
If all card reader errors have been cleared the next error code will be displayed or
"NONE"
if there
are no errors.
Press select button 1 will return to
"EROR"
.
Press select button 2 will scroll to the next routine.
"S-D"
– Display Device Summary Errors
Press select button 4 and the display will show one of the following:
-
"SDC"
, indicating no display device communication for 5 seconds.
-
"SDXX"
, error code number
“XX”
.
Press select button 1 will return to
"S-D"
if all display device errors have not been cleared.
If all display device errors have been cleared the next error code will be displayed or
"NONE"
if there
are no errors.
Press select button 1 will return to
"EROR"
.
Press select button 2 will scroll to the next routine.
Summary of Contents for DN504P
Page 50: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 50 of 100 CAN T READ THE DISPLAY...
Page 51: ...PARTS LIST P SERIES Page 51 of 100 Chameleon 6 Select 7 Column...
Page 52: ...PARTS LIST P SERIES Page 52 of 100 LMV 8 Select 7 Column...
Page 68: ...PARTS LIST P SERIES Page 68 of 100 SELECT PANEL LMV 9 10 6 4 3 2 1...
Page 69: ...PARTS LIST P SERIES Page 69 of 100 SELECT PANEL CHAMELEON 1 4 8 3 6 7 5 5...
Page 76: ...PARTS LIST P SERIES Page 76 of 100 INNER DOOR ALL 7 3 8 1 A2 4 6 10 9 2 5 12...
Page 78: ...PARTS LIST P SERIES Page 78 of 100 HARNESSING Single Board Controller 3 9 5 6 2...
Page 80: ...PARTS LIST P SERIES Page 80 of 100 POWER DISTRIBUTION 7 11 9 10 5 3 4 2 14 8 1 17 19 18 20...
Page 88: ...PARTS LIST P SERIES Page 88 of 100 CHUTE ASSEMBLY 4 6 5 11 8 1 10...
Page 96: ...PARTS LIST P SERIES Page 96 of 100 SCREWS NUTS...
Page 98: ...PARTS LIST P SERIES Page 98 of 100 WASHERS BOLTS MISC HARDWARE...