PROGRAMMING P
SERIES
Page 20 of 100
*”RFRG” – REFRIGERATION ROUTINE
This function is used to electronically control the refrigeration operations of the vender. Press select button 4 will
enter “ENB#” with # showing the current “ENB” setting.
ENB#
-
Energy Conservation Enable Routine
This function is used to disable Energy Conservation “ENB0” or enable Energy Conservation
“ENB1”. When enabled the cabinet temperature will be allowed to rise to the programmed
storage level “STOR” during the following programmed time blocks.
Press select button 4 and the current “ENB#” setting (#) will start flashing.
Press select button 2 or 3 to scroll between “ENB0” and “ENB1”.
Press select button 4 with the display showing the setting you wish to use and the display will
return to a solid “ENB#”.
Press select button 2 to scroll to “STRT”.
“STRT”
-
Start Energy Conservation
This function is used to set the days and time to start Energy Conservation when “ENB1” is
selected.
Press select button 4 and “DAY” will show on the display.
“DAY”
-
Day to Start Setting
This function is used to set the days of the week to start Energy Conservation.
Press select button 4 and “xxx#: will show on the display, where xxx will be the day
of the week (i.e. MON, TUE, WED, THU, FRI, SAT, SUN, ALL) and # is 0 = disable,
1 = enable. With the display showing the day you wish to set press select button 4.
The # will start blinking. Press select button 2 or 3 to scroll between “xxx0” and
“xxx1”. Press select button 4 with the display showing the setting you wish to use.
Display will return to “xxx#”. Press select button 2 to scroll to the next day to set or
press select button 1 to return to “DAY”.
Press select button 2 to scroll to “HOUR”.
“HOUR”
- Start Hour and Minute Setting
This function is used to set the hours to start Energy Conservation.
Press select button 4 and “hhmm” will show on the display, where “hh” is the hour
(military time) and “mm” is the minute. “hh” will be blinking, indicating the hour
setting may be changed. Press select button 2 to scroll from 00 to 23. With the
display showing the hour you wish to start Energy Conservation, press select button
4. “mm” will start blinking, indicating the minute setting may be changed. Press
select button 2 to scroll from 00 to 59. With the display showing the minute you
wish to start Energy Conservation, press select button 4. The display will return to
“HOUR”.
Press select button 1 to return to “STRT”.
Press select button 2 to scroll to “STOP”.
“STOP”
- Stop Energy Conservation Setting
This function is used to set the days and time to stop Energy Conservation when “ENB1” is
selected.
Press select button 4 and “DAY” will show on the display.
“DAY”
-
Day To Stop Setting
This function is used to set the days of the week to stop Energy Conservation
and can be set in the same manner as Day to Start Setting.
“HOUR”
- Stop Hour and Minute Setting
This function is used to set the hours and minutes to stop Energy Conservation
and can be set in the same manner as Start Hour and Minute Setting.
Press select button 1 to return to “STOP”.
Press select button 2 to scroll to “DEGX”.
Summary of Contents for DN504P
Page 50: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 50 of 100 CAN T READ THE DISPLAY...
Page 51: ...PARTS LIST P SERIES Page 51 of 100 Chameleon 6 Select 7 Column...
Page 52: ...PARTS LIST P SERIES Page 52 of 100 LMV 8 Select 7 Column...
Page 68: ...PARTS LIST P SERIES Page 68 of 100 SELECT PANEL LMV 9 10 6 4 3 2 1...
Page 69: ...PARTS LIST P SERIES Page 69 of 100 SELECT PANEL CHAMELEON 1 4 8 3 6 7 5 5...
Page 76: ...PARTS LIST P SERIES Page 76 of 100 INNER DOOR ALL 7 3 8 1 A2 4 6 10 9 2 5 12...
Page 78: ...PARTS LIST P SERIES Page 78 of 100 HARNESSING Single Board Controller 3 9 5 6 2...
Page 80: ...PARTS LIST P SERIES Page 80 of 100 POWER DISTRIBUTION 7 11 9 10 5 3 4 2 14 8 1 17 19 18 20...
Page 88: ...PARTS LIST P SERIES Page 88 of 100 CHUTE ASSEMBLY 4 6 5 11 8 1 10...
Page 96: ...PARTS LIST P SERIES Page 96 of 100 SCREWS NUTS...
Page 98: ...PARTS LIST P SERIES Page 98 of 100 WASHERS BOLTS MISC HARDWARE...