TROUBLESHOOTING
38
SOLD OUT SWITCH
Check Sold out switch for
continuity.
Check harnessing and connections for
continuity (from J1 at the HT2 machine
board to sold out switches).
[For HT3 (J4) at board.]
Check wire from appropriate sold out
switch, back to J1 at the HT2 machine
board or J4 at HT3 board.
Replace the Board if necessary.
Vender is indicating Sold Out on a
column that contains product.
Replace if
necessary.