INSTALLATION & SETUP
15
Return
Press select button 1 to return to “Light”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
Refrigeration
This function is used to electronically control the refrigeration operations of the vender.
Press select button 1 will enter “Temperature”.
Temperature
(Default Temperature 35
0
F/15
0
C)
This function is used to set the average product temperature for initial pull down and reload
recovery.
Press select button 1 and “tt.tx” will show on the display where x is F (Fahrenheit) or C
(Celsius) and tt.t is the degrees.
Press and hold select button 1 to increase or decrease the number by 1F or 0.5C. Release
select button with the display showing the temperature you wish to use and display will
return to “Temperature”.
Press select buttons 1 & 2 to scroll to “Celsius or Fahrenheit”.
Celsius or Fahrenheit
This function is used to set the degree reading to Fahrenheit (F) or Celsius (C).
Press select button 1 and the current setting will show on the display. Press and hold
select button 1 to toggle between F and C. Release the select button with the display
showing the setting you wish to use and display will return to “Celsius or Fahrenheit”.
Press select buttons 1 & 2 to scroll to “Display”.
Display
This function is used to enable the Temperature to be displayed following the “Ice Cold Pepsi”
message.
Press select button 1 and “Display” will show on the display. Press select button 1 and the
current setting will be displayed (On or Off). Press and hold select button 1 to
toggle between “On” and “Off”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
Days
This function is used to set the days of the week to use Temperature Setting Routine.
Day of Week: Sunday Wednesday Saturday Return
Monday Thursday All Days
Tuesday Friday not found
Press select button 1 and “Monday #” will show on the display, where # is “0” (disable) or
“1” (enable). Press and hold select button 1 to toggle between “0” and “1”. Release the
select button with the display showing the setting you wish to use. Press select buttons 1
& 2 simultaneously to scroll through all available days, “All Days”, “not found”, and
“Return”. Press select button 1 at the “Return” prompt returns to “Days”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
Start
This function is used to set the hours and minutes for storage temperature to become active.
Press select button 1 and the current four-digit hour and minute setting will be displayed (24 hour)
Press & hold select button 1: Set Hours
Press & hold select button 2: Set Minutes
Press select buttons 1 & 2 simultaneously to move to the next item on the menu.
Summary of Contents for DNCB 501E
Page 26: ...MAJOR COMPONENT DESCRIPTION 25 HT2 UNIVERSAL CONTROLLER...
Page 42: ...WIRING DIAGRAMS AND SCHEMATICS 41 HT2...
Page 43: ...TROUBLESHOOTING 42 HT3...
Page 44: ...WIRING DIAGRAMS AND SCHEMATICS 43 Refrigeration Circuit Diagrams...
Page 45: ...WIRING DIAGRAMS AND SCHEMATICS 44...
Page 53: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 52 SELECT PANEL...
Page 55: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 54 T8 LIGHTING...
Page 59: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 58 INNER DOOR...
Page 71: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 70 CABINET INTERIOR...
Page 81: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 80 SCREWS NUTS...