TROUBLESHOOTING FLOWCHARTS
28
These charts are intended to isolate and correct most problems you might encounter.
ALL COINS ARE REJECTED
All coins are rejected.
Main Power
Disconnected.
Apply power
Blown Fuse
Check fuses and
replace if
necessary.
Loose connection.
Check cable at
coin mech and
controller board.
Jammed coin
mechanism.
Clear coins.
Weak springs on
changer gate.
Replace spring.
Acceptor gate partially
open.
Clean and reset
acceptor gate.
Dirty / faulty coin sensor.
Clean / Replace.
Incompatible coin
mechanism.
Replace with
approved coin
mechanism.
Defective coin
mechanism.
Replace with
known good
coin mechanism.
HT2 defective Universal
controller board or
HT3 Control Board.
Replace.
Check Prices
Reset Price
Check mech in
diagnostics
"Coin Mech".
Check reject
button / lever for
proper
adjustment.
Summary of Contents for DNCB 501E
Page 26: ...MAJOR COMPONENT DESCRIPTION 25 HT2 UNIVERSAL CONTROLLER...
Page 42: ...WIRING DIAGRAMS AND SCHEMATICS 41 HT2...
Page 43: ...TROUBLESHOOTING 42 HT3...
Page 44: ...WIRING DIAGRAMS AND SCHEMATICS 43 Refrigeration Circuit Diagrams...
Page 45: ...WIRING DIAGRAMS AND SCHEMATICS 44...
Page 53: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 52 SELECT PANEL...
Page 55: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 54 T8 LIGHTING...
Page 59: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 58 INNER DOOR...
Page 71: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 70 CABINET INTERIOR...
Page 81: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 80 SCREWS NUTS...