Operating Manual 

 

1/3 

 

DIGITAL CONTROLLER WITH DEFROST AND 

FANS MANAGEMENT 

XR06CX 

1. CONTENTS 

1.

 

Contents____________________________________________________________________________ 1

 

2.

 

General warnings _____________________________________________________________________ 1

 

3.

 

General description ___________________________________________________________________ 1

 

4.

 

Regulation __________________________________________________________________________ 1

 

5.

 

Defrost _____________________________________________________________________________ 1

 

6.

 

Fans _______________________________________________________________________________ 1

 

7.

 

Front panel commands ________________________________________________________________ 1

 

8.

 

Parameters__________________________________________________________________________ 2

 

9.

 

Digital inputs (ONLY XR03CX) __________________________________________________________ 2

 

10.

 

Installation and mounting _______________________________________________________________ 2

 

11.

 

Electrical connections _________________________________________________________________ 2

 

12.

 

How to use the hot key_________________________________________________________________ 2

 

13.

 

Alarm signalling ______________________________________________________________________ 2

 

14.

 

Technical data _______________________________________________________________________ 2

 

15.

 

Connections _________________________________________________________________________ 3

 

16.

 

Default setting values__________________________________________________________________ 3

 

 

2. GENERAL WARNINGS 

PLEASE READ BEFORE USING THIS MANUAL 

 

This manual is part of the product and should be kept near the instrument for easy and quick 
reference. 

 

The instrument shall not be used for purposes different from those described hereunder. It cannot be 
used as a safety device. 

 

Check the application limits before proceeding. 

SAFETY PRECAUTIONS 

 

Check the supply voltage is correct before connecting the instrument. 

 

Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden 
temperature changes with high atmospheric humidity to prevent  formation of condensation 

 

Warning: disconnect all electrical connections before any kind of maintenance. 

 

Fit the probe where it is not accessible by the End User. The instrument must not be opened. 

 

In case of failure or faulty operation send the instrument back to the distributor or to “Dixell S.p.A.” (see 
address) with a detailed description of the fault. 

 

Consider the maximum current which can be applied to each relay (see Technical Data). 

 

Ensure that the wires for probes, loads and the power supply are separated and far enough from each 
other, without crossing or intertwining. 

 

In case of applications in industrial environments, the use of mains filters (our mod. FT1) in parallel with 
inductive loads could be useful. 

3. GENERAL DESCRIPTION 

The 

XR06CX

format  32 x 74 x 60 mm

, is microprocessor based controller, suitable for applications 

on medium or low temperature ventilated refrigerating units. It has three relay outputs to control 

compressor, fan, and defrost which can be either electrical or reverse cycle (hot gas). The device is 

also provided with 2 NTC probe inputs, the first one for temperature control and the second one to be 

located onto the evaporator, to control the defrost termination temperature and to managed the fan 

and it’s provided with a configurable digital input. With the HOTKEY it’s possible to program the 

instrument in a quick and easy way. 

4. REGULATION 

The regulation is performed according to 

the temperature measured by the 

thermostat probe with a positive 

differential from the set point: if the 

temperature increases and reaches set 

point plus differential the compressor is 

started and then turned off when the 

temperature reaches the set point value 

again. 

 

In case of fault in the thermostat probe the start and stop of the compressor are timed through 

parameters “

Cy

” and “

Cn

”. 

5. DEFROST 

Two defrost modes are available through the “

td

” parameter: 

 

td=EL

 

 

defrost through electrical heater (compressor OFF) 

 

td=in 

 

hot gas  defrost (compressor ON).  

Other parameters are used to control the interval between defrost cycles (

id

) ), its maximum length 

(

Md

) and two defrost modes: timed or controlled by the evaporator’s probe. At the end of defrost 

dripping time is started, its length is set in the 

dt

 parameter. With 

dt=0

 the dripping time is disabled. 

6. FANS 

With 

FC

 parameter it can be selected the fans functioning: 

 

FC=cn 

 will switch ON and OFF with the compressor and

 not run

 during defrost 

 

FC=on 

 fans will run even if the compressor is off, and not run during defrost 

 

After defrost, there is a timed fan delay allowing for drip time, set by means of the “

Fd

” parameter. 

 

 

FC=cy 

 

fans will switch ON and OFF with the compressor and 

run

 during defrost 

 

FC=oY

 

 

fans will run continuously also during defrost. 

 

An additional parameter “

FS

” provides the setting of temperature, detected by the evaporator probe, 

above which the fans are always OFF. This is used to make sure circulation of air only if his 

temperature is lower than set in “

FS

” 

FANS AND DIGITAL INPUT 

When the digital input is configured as door switch 

iF=do

, fans and compressor status depends on the 

dC

 parameter value:  

 

dC=no 

 normal regulation; 

 

dC=Fn

 

 

fans OFF; 

 

dC=cP

 

 compressor OFF;  

 

dC=Fc

 

 compressor and fans OFF. 

When  

rd=y

, the regulation restart with door open alarm. 

7.  FRONT PANEL COMMANDS 

  

To display target set point, in 
programming mode it selects a 
parameter or confirm an 
operation 

 

To start a manual defrost  

 

In programming mode it browses 
the parameter codes or increases 
the displayed value 

 

AUX

 

In programming mode it browses 
the parameter codes or 
decreases the displayed value 

 

KEYS COMBINATION 

 

+

 

 

To lock or unlock the keyboard

 

 

+

 

 

To enter in programming mode 

 

+

 

 

To return to room temperature display

 

 

LED 

MODE 

SIGNIFICATO 

On 

Compressor enabled 

 

Flashing 

Anti short cycle delay enabled (AC parameter) 

On 

Defrost in progress 

 

Flashing 

Dripping in progress 

On 

Fans output enabled 

 

Flashing 

Fans delay after defrost 

On 

Measurement unit  

 

Flashing 

Programming mode 

On 

Measurement unit 

 

Flashing 

Programming mode 

HOW TO SEE THE SET POINT 

 

1.

 

Push and immediately release the 

SET 

key, the set point will be showed; 

2.

 

Push and immediately release the 

SET

 key or wait about 5s to return to normal visualisation. 

HOW TO CHANGE THE SETPOINT 

 

1.

 

Push the SET key for more than 2 seconds to change the Set point value; 

2.

 

The value of the set point will be displayed and the “°C” or “°F” LED starts blinking; 

3.

 

To change the Set value push the   or   arrows. 

4.

 

To memorise the new set point value push the SET key again or wait 10s. 

HOW TO START A MANUAL DEFROST 

 

Push the 

DEF 

 key for more than 2 seconds and a manual defrost will start 

HOW TO CHANGE A PARAMETER VALUE 

 

To change the parameter’s value operate as follows:  

1.

 

Enter the Programming mode by pressing the 

SET

 keys for 3s (“

°C” or “°F”

  LED starts 

blinking). 

2.

 

Select the required parameter. Press the “

SET

” key to display its value 

3.

 

Use   or   to change its value. 

4.

 

Press “

SET

” to store the new value and move to the following parameter. 

To exit

: Press 

SET

+   or wait 15s without pressing a key. 

NOTE

: the set value is stored even when the procedure is exited by waiting the time-out to expire. 

HIDDEN MENU 

The hidden menu includes all the parameters of the instrument. 

HOW TO ENTER THE HIDDEN MENU 

1.

 

Enter the Programming mode by pressing the 

SET

 keys for 3s (“

°C” or “°F”

  LED starts 

blinking). 

2.

 

Released the keys, then push again the 

SET

 keys for more than 7s. The L2 label will be 

displayed immediately followed from the Hy parameter.  

NOW YOU ARE IN THE HIDDEN MENU.

 

3.

 

Select the required parameter. 

4.

 

Press the “

SET

” key to display its value 

5.

 

Use   or   to change its value. 

6.

 

Press “

SET

” to store the new value and move to the following parameter. 

To exit

: Press 

SET

+   or wait 15s without pressing a key. 

NOTE1: 

if there aren’t any parameter in L1, after 3s the “nP” message is displayed. Keep the keys 

pushed till the L2 message is displayed.  

NOTE2

: the set value is stored even when the procedure is exited by waiting the time-out to expire. 

HOW TO MOVE A PARAMETER FROM THE HIDDEN MENU TO THE FIRST 
LEVEL AND VICEVERSA. 

Each parameter present in the HIDDEN MENU can be removed or put into “THE FIRST LEVEL” (user 

level) by pressing 

SET

+  . In HIDDEN MENU when a parameter is present in First Level the decimal 

point is on. 

TO LOCK THE KEYBOARD 

 

1.

 

Keep pressed for more than 3s the   and   keys. 

2.

 

The “

OF

” message will be displayed and the keyboard will be locked. If a key is pressed more 

than 3s the “OF” message will be displayed. 

TO UNLOCK THE KEYBOARD 

 

Keep pressed together for more than 3s the   and   keys till the 

“on” 

message will be displayed. 