31
Large flow in
overboard dump
line
Leaking relief valve.
Clean relief valve and reset. If valve
continues to leak, replace.
Large flow in
overboard dump
line
Overboard dump valve
left open.
Close valve.
Too many heaters on for
load on system.
Refer to table to determine proper
number of heaters on or shut one heater
off and monitor temperature.
System will not
run, fault light is
on
No water is coming to
system. Float switch
shut off.
Supply water to system and purge. Make
sure that water is flowing out of system
through umbilical hose.
Faulty float switch.
Repair or replace float switch.
Overheated water in the
heater tank.
Make sure that water is flowing through
the system.
No water in heater tank.
Re-prime system, making sure that
water is flowing through system.
Over temperature
control needs
adjustment.
Readjust over temperature controls,
whichever one is turning the system off if
temperature of water is low.
Faulty over temperature
switch.
Determine which over temperature
switch is open circuited and replace.
Refer to the electrical schematics for
wiring details.
System will not
run, pump
overload fault
light is on
Pump overload relay has
tripped.
Possible low voltage, single phase or
incorrect frequency. Check the input
voltage and frequency. Measure the
current on the pump motor to see if it's
within rating. Reset overload and start
system again.
Faulty fault indicator
relay, R1/R2.
Replace.
Faulty overload relay.
Replace.
Inlet pressure to
pump is low
Faulty pressure
regulator.
Replace.
Low pressure to system,
below 3.5 bar.
Increase pressure and flow rate to the
system.
Pump varies in
speed
Belts slipping.
Check tension on belts. If tension is
loose, tighten belt by adjusting tension
bolts on motor mount.
Check belts condition. If belts are torn,
ragged, or in poor condition, replace.
PROBLEM
POSSIBLE CAUSE
SOLUTION
Summary of Contents for MHE-02
Page 2: ...Intentionally Blank...
Page 4: ...ii Approval Sheet KI OM 523 R2 Intentionally Blank...
Page 8: ...vi Data Sheet KI OM 523 R2 Intentionally Blank...
Page 10: ...viii Disclaimer KI OM 523 R2 Intentionally Blank...
Page 12: ...x Confidential Information KI OM 523 R2 Intentionally Blank...
Page 14: ...xii Warranty KI OM 523 R2 Intentionally Blank...
Page 16: ...xiv List of Tables and Figures KI OM 523 R2 Intentionally Blank...
Page 42: ...26 Chapter 4 KI OM 523 R2 Intentionally Blank...
Page 50: ...34 Chapter 5 KI OM 523 R2 Intentionally Blank...
Page 58: ...42 APPENDIX B KI OM 523 R2 Intentionally Blank...
Page 61: ...45 KI OM 523 R2 APPENDIX D APPENDIX D WIRING DIAGRAMS...
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ...46 KI OM 523 R2 APPENDIX E APPENDIX E PIPING AND FLOW SCHEMATIC...
Page 66: ......
Page 67: ...47 KI OM 523 R2 APPENDIX F APPENDIX F RKC CB100 DIGITAL CONTROLLER MANUAL...
Page 80: ...48 KI OM 523 R2 APPENDIX G APPENDIX G BELIMO CONTROL VALVE MANUAL...
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ......
Page 87: ...49 KI OM 523 R2 APPENDIX H APPENDIX H WATER PRESSURE REDUCING VALVE...
Page 88: ...I...
Page 89: ...bar bar bar bar...
Page 90: ......
Page 91: ...Nominal flow rates...
Page 92: ......
Page 93: ......
Page 94: ...50 KI OM 523 R2 APPENDIX I APPENDIX I CAT TRIPLEX PUMP MANUAL MODEL 1050...
Page 95: ......
Page 96: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 106: ......
Page 107: ...51 KI OM 523 R2 APPENDIX J APPENDIX J PULSATION DAMPENER...
Page 108: ......
Page 109: ......
Page 110: ...52 KI OM 523 R2 APPENDIX K APPENDIX K PRESSURE REGULATOR...
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ...53 KI OM 523 R2 APPENDIX L APPENDIX L FLOAT SWITCH...
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......