Frecuency Manual Reference
Pre-Use
• Perform pre-use inspection to ensure operating correctly. 4.3
As Required
1. Replace Filter 5.4
Every (12) months Inspect Basic Components
1. Clean unreadable labels and exterior surfaces
2. Capture Arm: Check for tears in flex hoses and fitting of hose clamps
3. Cabinet: Look for loose wiring.
5.3 Routine Maintenance Schedule
5.4 Servicing Filter
The manufacturer recommends the following routine maintenance based on light-duty use in normal operating conditions. Service more frequently if the
unit is used in severe conditions.
1.
Review Maintenance Safety in Section 5.1
2.
Turn off power and disconnect input power cord.
3.
All components should be supported to avoid falling damage or injury to operator.
4.
Support the filter bracket while unbolting the knobs from the connecting rods.
5.
Remove the filter bracket.
6.
Remove the connecting rods to ensure the filter is not damaged during removal.
7.
Remove filter gently so as to minimize agitating dirt and dust, and place it in a bag/container.
8.
Clean filter:
•
Use clean/dry air only at a pressure not more than 550 kPa at 30 cm from media.
•
Direct the compressed air through the filter from the clean side, running the nozzle up and down the filter pleats.
•
Do not bring the nozzle in contact with the filter media as damage is likely to occur.
9.
Inspect filter for any damage and replace if necessary.
10.
If necessary, clean filter brackets of dirt and debris.
11.
Reassemble:
•
Install the clean filter
•
Install the connecting rods, ensuring the filter is not damaged during installation.
•
Install the filter bracket.
•
Install the Knobs on the connecting rods with sufficient tightness.
Quantity
Hardware
1
Motor Blower Assembly
4
3/8” Threaded Rod, 91 cm Length
8
3/8” Threaded Knob
1
Filter Compression Plate Assembly
1
Filter Cartridge
• Place Filter in final location.
• Install the Connecting Rods, ensuring the Filter is not damaged during installation.
• Tighten left Knobs to hold Connecting Rods.
• Install Right Filter Bracket.
• Tighten right Knobs to Lock Filter.