ASURITY

TM

CONDENSATE MANAGEMENT

PAGE

 

2

 

INTRODUCTION

SAFETY INFORMATION 

Please read, understand, and follow all safety instructions. Failure to follow 

instructions may result in property damage, serious injury, or death.

 

DANGER

    

ALWAYS

 disconnect power prior to moving, adjusting, or servicing 

pump or attached systems.

 

DO NOT 

use this pump in the presence of 

spraying or standing water. Failure to do so could result in a fatal electric 

shock

.

WARNING: FIRE AND EXPLOSION HAZARD

  

DO NOT

 use this pump to move flammable or explosive liquids.

 

DO 

NOT

 

use this pump in explosive or flammable environments.

 

 Carbon monoxide hazard. Ensure that pump is mounted away from heat   

exchanger or wiring. If you are unsure of any items in this manual, please   

consult a professional and 

DO NOT

 

attempt to install this product.

CALIFORNIA PROPOSITION 65

  

 This product may contain chemicals known to the state of California to 

cause cancer, birth defects, or other reproductive harm. Wash hands 

after handling this product. 

CAUTION: FLOOD RISK

  

 Personal injury or property damage can result from an inoperative 

pump. If a flood has occurred, 

DO NOT

 walk in wet area until all power 

has been turned off. Check with local electric company or a qualified 

electrician before disconnecting any electrical service prior to pump 

removal. 

WARNING

 

    

Supply voltage and frequency must match what is shown on pump 

nameplate. Source voltages lower than the rated supply can reduce 

performance and cause pump to overheat. 

    

Pump must be level and should be mounted to or placed on a solid 

surface or floor. 

  

 DO NOT

 cover pump air vents. Pump is air cooled. 

DO NOT

 cover 

vent holes located on top or sides of the pump housing. Pump may be 

operated continuously as long as air vents are not covered.

 

 Pump should be stored indoors. The chosen location should be clean    

  and dry.

  This appliance is not intended for use by persons (including children) 

      with reduced physical, sensory or mental capabilities, or lack of   

 

  experience and knowledge, unless they have been given supervision or    

Summary of Contents for ASURITY PROCP-22S

Page 1: ...Installation Instructions Standard Applications Models PROCP 22S PROCP 22S 230 PROCP 22ST PROCP 22ST 230 Condensate Pump Pro...

Page 2: ...r birth defects or other reproductive harm Wash hands after handling this product CAUTION FLOOD RISK Personal injury or property damage can result from an inoperative pump If a flood has occurred DO N...

Page 3: ...ter from the appliance When water collected reaches sufficient level inside pump tank pump switches on and pumps water to a remote location for disposal When tank is sufficiently empty pump automatica...

Page 4: ...densate Pump 1 B Inlet Hole Covers 3 PROCP 22S PROCP 22ST PROCP 22S 230 PROCP 22ST 230 Rated Voltage 120 Volts 60Hz 220 Volts 60 Hz Rated Current Draw 1 9 Amps 1 0 Amps Head Height 22 ft maximum 22 ft...

Page 5: ...ndensate pump location 1B ATTACH TO WALL Attach condensate pump with screws 8 between mounting tabs OPTION REVERSE TOP IF NECESSARY Pump top may be rotated 180 to allow access to pump outlet or power...

Page 6: ...TLET TUBE CONNECTION Attach plastic tubing to check valve and secure with hose clamp Route tubing up and away from condensate pump avoid compressing or kinking tubing 1 2 3 8 Clear vinyl plastic tubin...

Page 7: ...ap should be used INLET COVERS 5 INSTALL INLET COVERS Insert inlet covers in remaining condensate pump inlet holes Inlet holes Orificios de entrada Inlet tubing Tuber a de entrada Inlet holes Orificio...

Page 8: ...uce the risk of electric shock be certain that it is connected only to a properly grounded grounding type receptacle This pump must be properly connected to power following the National Electric Code...

Page 9: ...ian 3 The modification meets code compliant requirements according to the local authority This modification does not void the factory warranty Final installations should always be inspected and approv...

Page 10: ...TENANCE AND DISASSEMBLY ALWAYS disconnect power before performing maintenance Pump and deck may be removed from tank by pushing tabs located on tank sides away from deck while lifting on pump cover Pe...

Page 11: ...s stuck Return pump to place of purchase if under warranty Pump will not shut off 1 Outlet flow is blocked 1 Check outlet tubing to ensure that it is not kinked or blocked Clear blocked tubing of slim...

Page 12: ...s despu s de manipular este producto PRECAUCI N RIESGO DE INUNDACI N Una bomba que no funcione puede producir lesiones personales o da os a la propiedad Si se produce una inundaci n NO camine en el re...

Page 13: ...o el tanque est lo suficientemente vac o la bomba se apaga autom ticamente La bomba tiene capacidad para elevar el agua hasta 6 10 m y est equipada con una v lvula de control que evita que el agua se...

Page 14: ...ROCP 22S PROCP 22ST PROCP 22S 230 PROCP 22ST 230 Voltaje calificado 120 voltios 60 Hz 220 voltios 60 Hz Consumo calificado de corriente 1 9 amperios 1 0 amperios Alto de cabezales M ximo de 4 87 m M x...

Page 15: ...Fije la bomba de condensaci n con los tornillos 20 32 cm entre las leng etas de montaje OPCI N 2 INVIERTA LA PARTE SUPERIOR SI FUERA NECESARIO La parte superior de la bomba puede girar 180 para permi...

Page 16: ...ALIDA Fije el tubo de pl stico para verificar la v lvula y asegurarlo con la abrazadera para manguera Gu e la tuber a hacia arriba y lejos de la bomba de condensaci n Evite comprimir o retorcer la tub...

Page 17: ...ber usar una trampa pl stica CUBIERTA 5 INSTALE LAS CUBIERTAS DE ENTRADA Coloque las cubiertas de entrada en los orificios de entrada restantes de la bomba de condensaci n Inlet holes Orificios de ent...

Page 18: ...la garant a y podr a provocar una descarga el ctrica fatal Y W G R Y W G R A 6 SYSTEM T STAT Com Run OVERFLOW SWITCH 24V 1A Max Shut Down Circuit Shut Down Circuit Overflow Switch is normally closed...

Page 19: ...ectado a tierra Esta bomba se debe conectar a la alimentaci n de forma adecuada siguiendo el C digo el ctrico nacional NEC por sus siglas en ingl s Si no sigue estas advertencias anular la garant a y...

Page 20: ...e la parte superior de la bomba Aseg rese de que el agua est bombeando por el tubo de salida 2 PROBANDO EL INTERRUPTOR DE DESBORDAMIENTO SI EST CONECTADO Retire la parte superior de la bomba del tanqu...

Page 21: ...vanta la cubierta de la bomba Inspeccione peri dicamente el tanque de la bomba de condensaci n para asegurarse de que est libre de suciedad o lodo acumulados NO use limpiadores a base de solventes Lim...

Page 22: ...be encenderse el ventilador debe girar visiblemente a trav s de la parte superior de la cubierta y el ventilador debe escucharse 2 El flujo de entrada de la bomba de condensaci n excede el flujo de sa...

Page 23: ...v o al punto designado en la autorizaci n de devoluci n de la Compa a Esta garant a es limitada y reemplazar cualquier otra garant a expresa o impl cita e incluye pero no se limita a cualquier otra ga...

Page 24: ...Diversitech Corporation Duluth GA 30097 800 995 2222 DOC172636 AsurityTM is a registered trademark of DiversiTech Corporation 2020 DiversiTech Corporation...

Reviews: