Section 5: Page 56 of 87
Data Export
The Data Export screen allows the Dive Master to set up data export capabilities for use with external
systems.
The Multicast Network Settings section allows
the Dive Master to choose a Broadcast Address
and Port Number for a User Datagram Protocol
(UDP) interface to allow diver data to be
transmitted on the network. This allows other
systems to easily import the information for
data collection and processing. One such
system is HYPACK® (www.hypack.com).
The format of the datagram is a comma
delimited string of values for each diver with the
following fields:
•
Diver6 Prefix/Beginning of string ($DIVER6)
•
Diver # (up to 3 digits)
•
Diver Name
•
Range (meters)
•
Azimuth (degrees)
•
Depth (meters)
•
Water Temperature (Celsius)
•
Maximum Depth (deepest diver has gone)
•
Tank Pressure 1 (BAR) (or empty string if no
data exists)
•
Tank Pressure 2 (BAR) (or empty string if no
data exists)
The GPX Export section allows the Dive Master
to choose if GPX compatible track files are
exported during dives. The Dive Master can
turn off the exporting (Export None) or export
craft only, diver only, or both craft and diver
tracks. The GPX files can be opened by any
application that supports the format (Figure
47).
Dive Log Maintenance
Over time, a large quantity of dive logs may accumulate and take up an abundance of storage space. The
Dive Log Maintenance screen (Figure 48) allows the Dive Master to delete files within specific time frames
to help free up space. A confirmation box will be presented to ensure the Dive Master definitely wants
to delete the files.