Diver6 User Manual
Section 5: Page 54 of 87
Global Alarms
The Global Alarms screen (Figure 44) displays system wide alarms and are organized into categories. A
default set of global values is provided and can be enabled/disabled by checking/unchecking the box
beside the particular alarm. Pressing the
Reset Global Alarms to Factory Defaults
button will restore the
values to their default states. The units displayed can be toggled between U.S. (PSI, Feet, Fahrenheit) and
Metric (Bar, Meters, Celsius) by clicking the
Toggle Units
button. Clicking the
OK
button will save the
changes and the
Cancel
button will abort.
When saving new global alarm values, the software will scan all diver alarms to update any out of range
values and display a dialog box with all divers that were adjusted.
Figure 44: Communication – Global Alarms Screen
Alarm
Default Value
Triggered When
Main Low
725 psi
Falls below value
Remaining Air Time
10 mins
Falls below value
Max Depth Greater Than Plan
NO
Diver depth exceeds plan depth
Max Depth
164 ft.
Exceeds value
Ascent Rate
59 ft./min
Diver ascends to quickly and exceeds rate
Water Temp Min
50 F
Water temperature falls below value
Water Temp Max
77 F
Water temperature exceeds value
Acoustics
5 transmissions
Fails to receive a number of responses
Max Range
984 ft.
Exceeds value