background image

DTK-U/DTK-U 

DTK-U/DTK-U Online UPS 

USER MANUAL 

Uninterruptible Power Supply System 

Version: 1.0 

INT-100

209

-001 Rev

 1   

 

 

Summary of Contents for DTK-UPS1000R+

Page 1: ...DTK UPS1000R DTK UPS1500R DTK UPS2000R DTK UPS3000R Online UPS USER MANUAL Uninterruptible Power Supply System Version 1 0 INT 100209 001 Rev 1...

Page 2: ...2 Operating principle 6 2 3 Install the UPS 6 2 4 Setup the UPS 7 2 5 Battery Replacement 10 2 6 Battery Kit Assembly 12 3 Operations 14 3 1 Button operation 14 3 2 LCD Panel 14 3 3 Audible Alarm 16 3...

Page 3: ...rip over them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only to an eart...

Page 4: ...oltage exists in the terminals of high capability capacitor such as BUS capacitors To avoid electrical shock turn off the unit and unplug it form the AC power source before servicing the battery Only...

Page 5: ...V 0 12 V 8 0 Ah NPW45 12 HB 12 V 7 5 Ah NPW45 12FR V 0 12 V 7 5 Ah UXW580 12 HB 12 V 9 0 Ah UXW580 12 FR V 0 12 V 9 0 Ah NPX 35 HB 12 V 8 0 Ah NPX 35 FR V 0 12 V 8 0 Ah KUNG LONG BATTERIES INDUSTRIAL...

Page 6: ...e when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manua...

Page 7: ...r panel view DTK UPS1000R DTK UPS1500R DTK UPS2000R DTK UPS3000R 1 Programmable outlets connect to non critical loads 2 Output receptacles connect to mission critical loads 3 AC input 4 Network Fax Mo...

Page 8: ...arg converter battery dynam UPS output Dynamic Bypass The UPS is composed of mains input EMI RFI filters rectifier PFC inverter battery charger DC to DC converter battery dynamic bypass and UPS output...

Page 9: ...to keep UPS normal operation at full load UPS 3 Place UPS It s equipped with fan for cooling Therefore place the UPS in a well ventilated area It s required to maintain minimum clearance of 100mm in t...

Page 10: ...s available connect them serially An example is shown in the diagram below connecting the second battery connector of the first battery pack to the first battery connector of the second battery pack 5...

Page 11: ...and general outlets Please connect non critical devices to the programmable outlets and critical devices to the general outlets During power failure you may extend the backup time to critical devices...

Page 12: ...tallation If there no screen shows 1 minute after inserting the CD please execute setup exe file for initiating software installation 2 Follow the on screen instructions to install the software 3 When...

Page 13: ...ry wires Pull out the battery box by removing two screws on the front panel Step 4 Step 5 Step 6 Remove the top cover of battery box and replace the inside batteries After replacing the batteries put...

Page 14: ...ow chart Step 3 Put assembled battery packs on one side of plastic shells Step 4 Cover the other side of plastic shell as below chart Then battery kit is assembly well 3 battery kit Step 1 Remove adhe...

Page 15: ...4 Cover the other side of plastic shell as below chart Then battery kit is assembly well 6 battery kit Step 1 Remove adhesive tapes Step 2 Connect all battery terminals by following below chart Step...

Page 16: ...ey Press this button to confirm selection in UPS setting mode Select Button Switch LCD message Press this button to change the LCD message for input voltage input frequency input current battery volta...

Page 17: ...equency load current and load percent k kilo W watt V voltage A ampere percent centigrade degree Hz frequency Load information Indicates the load level by 0 24 25 49 50 74 and 75 100 Indicates overloa...

Page 18: ...Display content Meaning ENA Enable DIS Disable ESC Escape HLS High loss LLS Low loss AO Active open AC Active close EAT Estimated autonomy time RAT Running autonomy time SD Shutdown OK OK ON ON BL Ba...

Page 19: ...27Vac 127Vac is not applicable in USA region 02 Frequency Converter enable disable Interface Setting Parameter 2 Enable or disable converter mode You may choose the following two options CF ENA conver...

Page 20: ...the acceptable high voltage point and acceptable low voltage point for Bypass mode by pressing the Down key or Up key HLS Bypass high voltage point 120 140 setting the high voltage point from 120Vac t...

Page 21: ...programmable outlets which connect to non critical devices on battery mode Default 999 11 Autonomy limitation setting Interface Setting Parameter 2 Set up backup time on battery mode for general outl...

Page 22: ...Default 2 36V cell 15 Charger float voltage setting Interface Setting Parameter 2 Set up the charger float voltage 2 20 2 33 setting the charger float voltage from 2 20 V cell to 2 33V cell Default 2...

Page 23: ...gulation range UPS will bypass voltage to output for energy saving The UPS will also charge the battery at ECO mode Frequency Converter mode When input frequency is within 40 Hz to 70 Hz the UPS can b...

Page 24: ...ery second Over input current Sounding 2 beep every 10 seconds Battery is not connected Sounding every 2 seconds Over Charge Sounding every 2 seconds Site wiring fault Sounding every 2 seconds EPO ena...

Page 25: ...ies are connected well Fault code is shown as 27 on LCD display and alarm is continuously sounding Battery voltage is too high or the charger is fault Contact your dealer Fault code is shown as 28 on...

Page 26: ...A on LCD display and alarm is continuously sounding The short circuit occurs on the charger output Check if battery wiring of connected external pack is in short circuit status Fault code is shown as...

Page 27: ...rged battery 91 full charged battery ECO Mode 96 full charged battery Battery Mode 88 90 BATTERY Battery Type 12V 9AH 12V 9AH 12V 9AH 12V 9AH Numbers 2 3 4 6 Recharge Time 3 hours recover to 95 capaci...

Page 28: ...0Hz 1 2000VA 1930W 16A 125Vac input 2000VA 1850W 16 7A 120Vac input 2000VA 1740W 17 4A 115Vac input 2000VA 1640W 18 2A 110Vac input 1800VA 1500W 18A 100Vac input DTK UPS3000R 100 125Vac 50 60Hz 24A 1...

Page 29: ...with UPS Models DTK UPS1000R DTK UPS1500R DTK UPS2000R DTK UPS3000R Battery Type 12V 9Ah 12V 9Ah 12V 9Ah 12V 9Ah Battery Numbers 4 6 8 12 Dimensions DxWxH mm 380 x 438 x 88 480 x 438 x 88 600 x 438 x...

Reviews: