29
DEU
ENG
DEU
Device overview
ENG
(D)
Connection terminal for lamp/corresponding supply lines
Normally Open (2)
(E)
Connection terminal for neutral conductor (N)
4.1 Technical Data
Short designation of the device
DT5649
Supply voltage
230 V / 50 Hz
Max. power consumption
5 A
Standby power consumption
0.2 W
Max. switching power
1150 W
Load type
resistive load
Relay
changeover contact
Line type and line section
rigid and flexible line, 0.75-1.5 mm²
Installation
only in switchboxes according to DIN
49073-1
Protection type
IP20
Measurement category
CAT III
Ambient temperature
5 to 35 °C
Dimensions (W x H x D)
71 x 71 x 37 mm
Weight
43 g
Radio frequency
868.3 MHz/869.525 MHz
Receiver category
SRD category 2