32
ENG
DEUDEU
Commissioning
ENG
1. Disconnect from the mains network and secure against unintended
activation.
2. If necessary pull off the rocker from the frame of the respective switch.
3. Pull off the frame and the clamping/support piece from the switch.
4. Loosen the cabling and remove the existing switch if necessary.
5. Connect the wiring as follows:
Switching off
Conductor to lamp/light to connection terminal 2.
(see fig. 1 page 2)
Intermediate switch circuit
Corresponding supply lines to the inter-
mediate switch at connection terminals 1 and 2. (see fig. 3 page 3)
Multiway switching circuit
Corresponding supply lines to the tog-
gle switch at connection terminals 1 and 2. (see fig. 4 page 4)
6. Connect the external conductor to connection terminal L.
7. Connect the neutral conductor to connection terminal N.
8. Connect the neutral conductor of the lamp to the neutral conductor
of the building installation.
9. Screw the device to the flush-type box.
The system key must be in the left upper corner for the installation.
10. Install the adapter to the rocker (see fig. 5 page 4).
11. Fix the rocker together with the adapter into the frame on the actuator
(see II in figure on the left). Both catches must fit to the oblong holes.
12. Connect to the mains network.
Summary of Contents for DT5649
Page 2: ...2 ENG DEU DEU 5 22 1x 1 DEU ENG 2 2 2x 2x 3 2 x 15 mm 3 2 x 25 mm Key SGTIN QR 1x...
Page 3: ...3 DEU ENG 2 3 A D E B C A D E B C...
Page 4: ...4 ENG DEU DEU 4 5 6...
Page 6: ...6 ENG DEU 10 Werkseinstellungen herstellen 20 11 Au erbetriebnahme 20 12 Entsorgen 21...
Page 23: ...23 DEU ENG DEU ENG 10 Resetting factory settings 36 11 Decommissioning 36 12 Disposal 37...
Page 41: ...Kopp K Alaska Athenis Ambiente Europa Paris Objekt HK 05 Milano Rivo Gira GD Standard...
Page 43: ......
Page 44: ...134457 1815...