12
IP2393EN
A
P
D
E
L
B
C
min 60 mm / 90°
S
Tab. 4.1
A
B
C
S
D
E
L
P min
200
190
20
170
120°
120
910
220
200
200
50
150
110°
220
100
220
50
170
90°
120
130
210
70
140
95°
150
170
220
100
120
95°
190
200
190
100
90
100°
220
150
220
150
70
95°
170
130
290
220
70
90°
150
4. Installation
The given operating and performance features can only be guaranteed with the use of DITEC ac-
cessories and safety devices. Unless otherwise specified, all measurements are expressed in mm.
4.1 Preliminary checks
Make sure the gate structure is sturdy and the hinges are lubricated and smooth.
If possible, fit an opening and closing stop. Otherwise, use the mechanical stops (integrated
for opening stop with PWR50AC, optional for closing stop with PWRFM, integrated for opening
and closing stops with PWR50H/HR) and/or the electromechanical limit switches (included for
PWR50HV) if available. The mechanical construction elements must comply with the requisites
of Standard EN12604.
The automation fastening point varies according to the space available and the gate to
be automated. The installer must therefore choose the best solution to ensure that the
system works correctly in each individual situation.
The installation measurements indicated in the table allow you to choose the values of [A] and [B]
on the basis of the required opening angle and in relation to the on-site spaces and overall dimen-
sions.
Increasing measurement [A], you reduce the approach speed during opening.
Reducing measurement [B], you increase the gate opening angle.
Measurements [A] and [B] must, however, be compatible with the effective motor stroke.