JT520 Operator’s Manual
Systems and Equipment - 91
Electric Strike System
CMW
Strobe light on drilling unit
does not work during total
test
Improper connections with
control module
Check connections and wiring
harness
Defective strobe light
1.
Disconnect strobe and connect to
external 12V power source.
2.
If strobe does not work, replace it.
Defective control module
Have control module checked or
replaced
Alarm on drilling unit does
not work during total test
Improper connections with
control module
Check connections and wiring
harness
Defective alarm
1.
Disconnect strobe and connect to
external 12V power source.
2.
If strobe does not work, replace it.
Defective control module
Have control module checked or
replaced
Strobe light and alarm on
drilling unit do not work
during total test
Improper connections with
control module
Check connections and wiring
harness
Defective control module
Have control module checked or
replaced
EC2 code displays and
current problem indicator is
on
Improper connections with
control module
Check cable connections on control
module and current transformer
Defective current transformer
1.
Disconnect current transformer.
2.
Check for 20-40 ohms from pin 1
to pin 4, 20-40 ohms from pin 1 to
pin 2, and less than 1 ohm from
pin 2 to pin 4.
Defective current transformer
cable
1.
Disconnect cable from
transformer and control module.
2.
Check continuity of cable.
3.
If continuity is zero or cable is
damaged, replace.
Defective control module
Have control module checked or
replaced
EV1 code displays and
voltage problem indicator is
on
Improper connection of voltage
limiter to ground stake
Check voltage limiter connection to
ground stake and verify that ground
stake is driven into the ground
Defective voltage limiter
Have voltage limiter checked or
replaced
Defective control module
Have control module checked or
replaced
Problem
Possible cause
Possible solution
Summary of Contents for JT520
Page 1: ...JT520 Issue 1 1 Operator s Manual CMW 053 1219...
Page 59: ...Prepare 58 JT520 Operator s Manual Check Supplies and Prepare Equipment CMW...
Page 63: ...Drive 62 JT520 Operator s Manual Shut Down Unit CMW...
Page 71: ...Transport 70 JT520 Operator s Manual Tow CMW...
Page 113: ...Systems and Equipment 112 JT520 Operator s Manual Drill Pipe CMW...
Page 117: ...Complete the Job 116 JT520 Operator s Manual Stow Tools CMW...
Page 141: ...Service 140 JT520 Operator s Manual As Needed CMW...
Page 145: ...Specifications 144 JT520 Operator s Manual CMW...
Page 148: ......
Page 149: ......
Page 150: ...JT520 Operator s Manual Service Record 149 CMW Service Record Service Performed Date Hours...
Page 151: ...CMW Service Record 150 JT520 Operator s Manual Service Performed Date Hours...