![DirectOut Technologies MADI.MONI User Manual Download Page 35](http://html1.mh-extra.com/html/directout-technologies/madi-moni/madi-moni_user-manual_2507567035.webp)
page 35 of 40
MADI.MONI Manual - Version 1.1
CHAPTER 5: Troubleshooting and Maintenance
CHAPTER 5: Troubleshooting and Maintenance
Troubleshooting
To identify a possible defect with the device please consult the following table.
If the fault cannot be resolved using these instructions, please contact your local
DirectOut representative or visit
support.directout.eu.
Issue
Possible reason
Solution
Device doesn’t
work.
Battery discharged.
Check that the power supply switch is
off and plug the device to a matching
charging device using the USB
connection. Check led ‘BATTERY-
CHARGE’.
Rare flashing led
codes after switch
on.
Low power - battery
discharged.
Check that the power supply switch is
off and plug the device to a matching
charging device using the USB
connection. Check led ‘BATTERY-
CHARGE’.
Optional SFP
Module:
Optical port does
not work.
Optic is dirty.
Use an air supply to carefully remove any
dust.
Never use objects for cleaning.
Optional SFP
Module:
Analysis of
Amplitude does
not work
SFP Module does not
support this feature.
Use appropriate SFP module. See
„Accessory“ on page 13.
No signal at the
output port.
Signal cable defective.
Exchange the signal cable.
No signal at the
output port.
Connections (input /
output) are mixed up.
Check the connections and change the
cables if necessary.
Maintenance
To clean the device, use a soft, dry cloth. To protect the surface, avoid using
cleaning agents.
The device should be switched off during the cleaning process.