![DirectOut Technologies MADI.MONI User Manual Download Page 24](http://html1.mh-extra.com/html/directout-technologies/madi-moni/madi-moni_user-manual_2507567024.webp)
page 24 of 40
MADI.MONI Manual - Version 1.1
CHAPTER 4: Operation
Display - Menu settings
Display
The individual parameter of a device setting is
indicated.
Input Source
BNC input is selected for analysis and monitoring.
SFP input is selected for analysis and monitoring.
Monitor Mode
Mono mode, monitoring of a single channel, left and right
are identical.
Stereo mode, monitoring of a channel pair,
odd number = left, even number = right
Scal
ing F
actor*
Scaling factor for monitoring 1 (44.1 / 48 kHz)
Scaling factor for monitoring 2 (88.2 / 96 kHz)
Scaling factor for monitoring 4 (176.4 / 192 kHz)
Output Source SFP
SFP MADI output follows the input selection
(parameter <S>)
SFP MADI output fed by SFP input
SFP MADI output fed by BNC input
* A 96k Frame input signal forces the scaling factor temporarily to 2 FS, overriding
this setting until a 48k Frame input signal is resumed.
Legend: c = cage = SFP, C = Channel = monitor channel mode