![DirectOut Technologies MADI.MONI User Manual Download Page 28](http://html1.mh-extra.com/html/directout-technologies/madi-moni/madi-moni_user-manual_2507567028.webp)
page 28 of 40
MADI.MONI Manual - Version 1.1
CHAPTER 4: Operation
Sample Rate
The sample rate (FS) of the selected input is measured and indicated by two green
leds. Base rates that deviate more than 0.1 % from the standard rates 44100 Hz or
48000 Hz are indicated by individual fl ashing codes of both leds.
Code
Meaning
LED Code
unlock
both leds OFF
FS < 44056 Hz
44.1 FLASHING green
48 OFF
FS = 44100 Hz ± 0.1 %
44.1 ON
48 OFF
44145 Hz < FS < 47952 Hz
both leds FLASHING
green
FS = 48000 Hz ± 0.1 %
44.1 OFF
48 ON
FS > 48049 Hz
44.1 OFF
48 FLASHING green