DirectOut Technologies MADI.MONI User Manual Download Page 1

MADI.MONI

User‘s Manual

Version 1.1

Summary of Contents for MADI.MONI

Page 1: ...MADI MONI User s Manual Version 1 1...

Page 2: ...ranteed that all product names products trademarks requisitions regulations guidelines speci cations and norms are free from trade mark rights of third parties All entries in this document have been t...

Page 3: ...e Parts Modules 9 First Aid in case of electric shock 9 Updates 10 Conditions of Warranty 10 Intended Operation 10 Conformity Certi cates 11 Contact 12 Contents 12 Accessory 13 CHAPTER 3 Installation...

Page 4: ...page 4 of 40 MADI MONI Manual Version 1 1 CHAPTER 5 Troubleshooting and Maintenance 35 Troubleshooting 35 Maintenance 35 CHAPTER 6 Technical Data 36 Index 37...

Page 5: ...l or Index Directory at the end of the document to locate help on a particular topic You can access more information and latest news by visiting on the DirectOut website at www directout eu Convention...

Page 6: ...48 88 2 96 176 4 192 kHz 12 5 USB Port USB 2 0 B plug for charging and rmware updates Analysing Features Sample Rate MADI Format Signal Amplitude Jitter Display Segment display to indicate channel vol...

Page 7: ...f the physical link and monitoring the audio signal serve the aim of solid operating conditions in MADI environments Typical applications include ensuring stable signal connections detection of cablin...

Page 8: ...at up Do not place the device close to heating sources e g heaters Observe the environmental conditions Do not dispose the device into fire water or other liquids Battery Safety Instructions WARNING T...

Page 9: ...sending parts for repair First Aid in case of electric shock WARNING Do not touch the person or his her clothing before power is turned off otherwise you risk sustaining an electric shock yourself Sep...

Page 10: ...nents that are essential for proper and intended operation of the device The date of purchase is applied for this period Consumable parts e g battery are excluded from warranty claims WARNING All clai...

Page 11: ...stances This device was constructed ful lling the directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC WEEE Directive on Waste Elec...

Page 12: ...5 100 Fax 49 0 3727 5665 101 www directout eu Manufacturer Leine Weser Labor GmbH Brabeckstr 121 30539 Hannover Germany Contents The contents of your MADI MONI package should include 1 x MADI MONI 1 x...

Page 13: ...OC3 STM1 Gigabit Ethernet Gigabit Fibre Channel Bandwidth from 100 Mbit s 1 050 Gbit s Bandwidth 155 Mbit s 1 250 Gbit s Laser FP FP Receiver Type PIN PIN Connector LC LC Wavelength TX min 1260 nm 12...

Page 14: ...s of 5 C and 45 C and a maximum relative humidity of 80 non condensing Ensure that the unit has suf cient air circulation for cooling CHAPTER 3 Installation Installing the Device 1 Open the packaging...

Page 15: ...okumente dotec_release_map pdf To update the rmware an installed USB Serial driver Windows and the Update Tool are necessary The software and the installation instructions are available at www directo...

Page 16: ...river download the USB Serial driver download the Installation Guide for USB Control Link http www directout eu en support downloads madi moni html follow the installation instructions in the Installa...

Page 17: ...r red led indicates low level and requires charging the battery To charge the battery switch off the device and and connect it to an external USB power supply or USB computer port NOTE If the battery...

Page 18: ...basic operation of the device Note that throughout this manual the abbreviation FS refers to sample rate or sample frequency So when dealing with scaling factors the following sample rates can be wri...

Page 19: ...ttery or rmware updates Signal Connections MADI MONI provides two MADI I Os coaxial BNC port SFP cage to connect other media carrying MADI signals e g bre single mode multi mode different wavelengths...

Page 20: ...tatus ON charging battery OFF no charge flashing 1 5 Hz NTC fault temperature alarm flashing 6 Hz battery defective Battery Level LED green yellow red indicating battery level while operation green ch...

Page 21: ...binations of the three LEDs traf c light The alphanumeric display monitors the signal level of the selected channel s for monitoring Using the navigation buttons it can be toggled to temporary display...

Page 22: ...OFF Channel selection not enabled MENU LED green indicates selection of menu to adjust device settings ON Menu settings enabled OFF Menu settings not enabled SET Push button Push to decrease level cha...

Page 23: ...output Highest volume level for headphone output WARNING The use of headphones at high volume may harm your hearing Display Channel selection Display The selected channel pair is indicated In stereo...

Page 24: ...tereo mode monitoring of a channel pair odd number left even number right Scaling Factor Scaling factor for monitoring 1 44 1 48 kHz Scaling factor for monitoring 2 88 2 96 kHz Scaling factor for moni...

Page 25: ...DI output fed by SFP input BNC MADI output fed by BNC input Display Brightness Display and led dim level 1 dark Display and led dim level 2 moderate Display and led dim level 3 light Display and led d...

Page 26: ...SFP I O not selected ON SFP I O selected BNC LED green indicating selection state of BNC input OFF BNC I O not selected ON BNC I O selected Sync The device is clocked by the selected input signal LOC...

Page 27: ...g of the parameter Legend c cage SFP C Channel monitor channel mode S x Input Source C x Monitor Mode F x Scaling Factor c x Output Source SFP b x Output Source BNC d x Display Brightness b BNC c SFP...

Page 28: ...rates that deviate more than 0 1 from the standard rates 44100 Hz or 48000 Hz are indicated by individual flashing codes of both leds Code Meaning LED Code unlock both leds OFF FS 44056 Hz 44 1 FLASH...

Page 29: ...y be used at 1 FS 2 FS and 4 FS Thus a 48k Frame MADI signal needs the scaling factor to be adjusted manually for proper monitoring see Display Menu settings on page 24 Code Meaning LED Code 48k Frame...

Page 30: ...s of 56 or 64 channels N are indicated by individual flashing codes of both leds Code Meaning LED Code channel count not constant both leds FLASHING alternately green N 56 channels 56ch FLASHING green...

Page 31: ...w power alarm LEFT FLASHING red MID OFF RIGHT OFF 300 mV low power warning LEFT ON yellow MID OFF RIGHT OFF 600 mV ok if SFP with DDM LEFT OFF MID ON green RIGHT OFF 800 mV high power warning LEFT OFF...

Page 32: ...nput is analysed The analysis results are indicated by traf c light leds Code Measured Jitter LED Code very poor LEFT FLASHING red MID OFF RIGHT OFF poor LEFT ON yellow MID OFF RIGHT OFF average LEFT...

Page 33: ...loop from BNC input to BNC output Press and hold VOL CH and MENU buttons for 5 seconds until C1 is displayed During the calibration process C2 C3 and C4 will be displayed When the calibration is done...

Page 34: ...page 34 of 40 MADI MONI Manual Version 1 1 CHAPTER 4 Operation This page is left blank intentionally...

Page 35: ...er battery discharged Check that the power supply switch is off and plug the device to a matching charging device using the USB connection Check led BATTERY CHARGE Optional SFP Module Optical port doe...

Page 36: ...ntal Conditions Operating temperature 5 C up to 45 C Relative humidity 10 80 non condensing MADI Port BNC coaxial 2 x BNC socket input output Impedance 75 0 3 V up to 0 6 V peak to peak MADI Port SFP...

Page 37: ...Contact 12 Contents 12 Conventions 5 D Defective Parts Modules 9 Display Channel selection 23 Level meter 25 Menu settings 24 Volume control 23 E Environmental Conditions 14 F Feature Summary 6 Firmw...

Page 38: ...page 38 of 40 MADI MONI Manual Version 1 1 NOTE...

Page 39: ...page 39 of 40 MADI MONI Manual Version 1 1 NOTE...

Page 40: ...DirectOut GmbH T 49 3727 5665 100 F 49 3727 5665 101 www directout eu Leipziger Strasse 32 09648 Mittweida Germany...

Reviews: