33
shock sensor harness, 4-pin connector
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while inputs longer than 0.8 seconds will
trigger full alarm sequence and report Zone Two. If installing an optional Directed Electronics dual stage sensor,
connect to the green wire as shown below. The diagram below eliminates the need for diodes to isolate the
sensors.
Diagram for adding optional Directed Electronics dual stage sensor to green wire (Zone 2):
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while inputs longer than 0.8 seconds will
trigger full alarm sequence and will also report Zone Two.
Do not use these for anything besides the plug-in shock sensor.
RED and BLACK: RED is (+)12V constant, BLACK is (-) ground
BLUE (-) multiplex input, zone 2
GREEN (-) multiplex input, zone 2