2005
Directed Electronics, Inc.
7
N1/3 WHITE (-) parking light input
Connect this wire to the “indicator light output” of the security system. Configure the security
system as a negative output.
N
NO
OTTEE:: This input will be enabled only with the ignition OFF (not usable during a remote start operation).
N1/4 WHITE/BROWN (-) turn signal input
Connect this wire to the “indicator light output” of the security system. Configure the security
system as a negative output.
N
NO
OTTEE:: The turn signal input will be ignored in the following case: The key is left in the ignition switch after
the ignition is turned OFF (and not taken out and insert again) and the “Prevent Door Locking if Key left in
Ignition” is enabled. In this case CAN-IM will ignore a valid arm/lock input and will automatically flash
the turn signals rapidly (100 msec on 100 msec off) for 5 seconds to notify the user.
N1/5 BLACK/WHITE (-) domelight input
Connect this wire to the “domelight supervision relay output” of the security system. Configure this
output as negative.
N
NO
OTTEE:: This input is effective only if the following conditions are met:
➤
➤
all doors are closed
➤
➤
the dome light switch is in the position “light when door opened”
➤
➤
the ignition is OFF
N1/6 YELLOW (+) ignition status output
Connect this wire to the “switched ignition input” of the security system.
N
NO
OTTEE:: The ignition output will be forced to the OFF state during the remote start operation so that the
security system will not be triggered.
N1/7 GREEN (-) door status output
Connect this wire to the “(-) door trigger input” of the security system.