2005
Directed Electronics, Inc.
11
N2/6 BROWN (-) not used
This input must not be connected. The function is not available.
N2/7 GRAY (-) hood status
Connect this wire to the “(-) hood pin input” of the security system.
Alarm Accessories (N3) Wire Connection
Guide
Alarm Accessories Harness Wiring Diagram
___
___
___
___
___
___
___
Alarm Accessories Harness Wiring Instructions
N3/1 WHITE/BLUE (-) front windows down input
Connect this wire to a channel output of the security system. Configure the security system output
type as “validity” .
N
NO
OTTEE:: This input is only valid with the ignition OFF.
➤
➤
If a short pulse (less than 1-second) is received on this input, and CAN-IM finds any of the front
windows above the “small vent” position, it will roll down the front window(s) to the “small vent”
position, else if it finds any of the front windows above the “large vent” position, it will roll down
the front window(s) to the “large vent” position. In any other case the input will be ignored. In no
case the windows will be rolled up.
➤
➤
If a long pulse (greater than 1-second) is received on this input, CAN-IM will roll down the
front window(s) as long as the input remains active.
➤
➤
This input is not valid during the execution of the comfort closure function after an arm/lock
command.
RED/WHITE
(-) Trunk release input
ORANGE/BLACK
(-) Radio input
GRAY/BLACK
(-) Fuel door release input
BROWN
(-) Headlight input
VIOLET/BLACK
(-) Sunroof input
WHITE/BLACK
(-) Rear windows down input
WHITE/BLUE
(-) Front windows down input
N3/1
N3/2
N3/3
N3/4
N3/5
N3/6
N3/7