Directed 933.MIT3 Installation Manual Download Page 18

18

933.MIT3 2.11.195.3 2012 Mitsubishi Lancer Evolution
©2022 VOXX•DEI LLC.  All rights reserved.

 

External Module Synchronization

LED

Description

Troubleshooting

(Flashes red, red,
then orange) x 10

OBDII feature not supported.

The diagnostic data bus was not detected, therefore the SmartStart features will be limited.

Active Ground When Running (Status)

LED

Description

Troubleshooting

Flashes green

Ground When Running (Status) command
received.

The module has initialized the remote start sequence.

Flashes red & orange

Ignition ON command received.

The module has received the Ignition ON command and is processing the remote start sequence.

Flashes green quickly

Start ON command received.

The module has received the Start ON command and is processing the remote start sequence.

Flashes red x 10

PTS shutdown error.

The PTS output from the module was not activated due to safety protection.

Flashes red x 21

CAN bus incorrectly detected.

Verify the CAN1 and CAN2 connections. Refer to “Installation (wiring diagrams & vehicle wiring
reference charts)” to check the connections.

Commands

LED

Description

Troubleshooting

Flashes orange x 1

LOCK command received.

If the bypass module fails to flash, it did not receive the signal. Commands can come from RF or D2D.

Flashes orange x 2

UNLOCK command received.

If the bypass module fails to flash, it did not receive the signal. Commands can come from RF or D2D.

Flashes orange x 3

TRUNK command received.

If the bypass module fails to flash, it did not receive the signal. Commands can come from RF or D2D.

Flashes orange x 4

AUX1 command received.

If the bypass module fails to flash, it did not receive the signal. Commands can come from RF or D2D.

Flashes orange x 5

AUX2 command received.

If the bypass module fails to flash, it did not receive the signal. Commands can come from RF or D2D.

Flashes orange x 6

AUX3 command received.

If the bypass module fails to flash, it did not receive the signal. Commands can come from RF or D2D.

Shutdown Codes

LED

Description

Troubleshooting

Flashes green x 1

Takeover successful.

Normal operation.

Flashes red x 1

Runsafe was not disabled.

No UNLOCK command was received prior to opening the door, or the 45 second timer expired in
takeover mode.

Flashes red x 2

Brake was not detected.

The brakes were not detected, which prevents the system from shutting down the vehicle.

Flashes red x 3

Smart key was not detected.

The smart key was not detected, which prevents the system from shutting down the vehicle.

Flashes red x 4

Speed was detected.

The vehicle was detected as moving, which prevents the system from shutting it down.

Summary of Contents for 933.MIT3

Page 1: ...DS3 DS4 933 MIT3 v2 11 195 3 2012 Mitsubishi Lancer Evolution...

Page 2: ...gramming for security only installations 13 Pairing remotes 14 Connecting the module 14 8556T Temperature Sensor 14 8504D Combo Sensor 14 RF Systems 14 When used in conjunction with SmartStart 15 D2D...

Page 3: ...Web or DirectLink DT mobile app 1 Disconnect the main module from any 12V power source 2 Connect the module to your computer using the XKLoader2 3 Follow the steps in the pop up window that will be d...

Page 4: ...y Door Lock Control Door Unlock Driver Priority Unlock Trunk Hatch Release Control of aftermarket alarm with OEM remote Fuel level EV battery level Immobilizer Bypass Data No Key Req d 3x LOCK START S...

Page 5: ...ils Firmware notes Fuses It is important to check that the fuses are positioned correctly in the module Proper fuse positioning is displayed on each wiring diagram Unless specified otherwise all conne...

Page 6: ...nel 3 1 2 4 5 6 Ignition Connector white 6 pin conn left side of steering column Ignition White pin 2 Starter Orange or Lt Blue pin 5 Accessory Lt Green pin 6 1 8 3 10 12 2 9 4 11 13 17 5 14 18 6 15 1...

Page 7: ...ction When using an external relay use a 1N4002 diode or larger 22 8 12 4 2 4 4 2 Security Only Mandatory Connections Remote Start Only Legend Remote Start Security Ground When Armed GWA Output Blue W...

Page 8: ...e Location Wire Color Connection H2 1 Lt Green Black Auto Headlight Shutoff Output dash fuse box brown 16 pin plug pin 16 yellow Remote Start Only H2 2 Blue White Ground When Armed GWA Output 3 Starte...

Page 9: ...H3 6 Red 12 Volt Input dash fuse box black 2 pin plug pin 1 white or black red 80A Mandatory H3 7 Lt Green Red Relay N O 12 Volt Input dash fuse box black 2 pin plug pin 1 white or black red 80A Remot...

Page 10: ...in white connector H5 Module Conn Pin Color Description H5 1 N A RF Loop H5 2 N A RF Loop D2D harness 4 pin white 1 and black 2 connectors H6 Module Conn Pin Color Description H6 1 Blue Data TX H6 2 B...

Page 11: ...Wait until the LED turns ON solid red before proceeding to the next step 3 Connect the remaining harnesses to the module 4 Turn the ignition ON or turn the knob to the RUN position 5 The LED will flas...

Page 12: ...until the LED turns ON solid orange then proceed to the next step 4 2 4 4 2 22 8 10 12 Must connect 12 pin FIRST Solid Solid DS3 DS4 Solid 1 Sec OR 3 Connect remaining harnesses to the module then pr...

Page 13: ...IRST Solid Solid DS3 DS4 Solid 1 Sec OR 3 Connect the remaining harnesses to the module Connect remaining harnesses 4 Make sure the key is inside the vehicle Insert and turn the key to the ON position...

Page 14: ...he system is configured as a remote starter the temperature is reported by the 8556T Temperature Sensor When security features are enabled it is reported by the 8504D Combo Sensor 8504D Combo Sensor T...

Page 15: ...Directed SmartStart 2 pin power harness when using the DS3 DS4 Power and ground will be provided by the D2D connector on the module Refer to the Directed SmartStart documentation for further details...

Page 16: ...mode sequence and shut down the remote start turn off the ignition engine stays running exit the vehicle with your keys shut all doors and press lock on the Directed remote To complete the manual read...

Page 17: ...feature error A feature config file mismatch was detected Please contact Technical Support Module Programming Error codes LED Description Troubleshooting Flashes red x 1 CAN2 not detected Check the C...

Page 18: ...t receive the signal Commands can come from RF or D2D Flashes orange x 2 UNLOCK command received If the bypass module fails to flash it did not receive the signal Commands can come from RF or D2D Flas...

Page 19: ...r 1 second then solid red Solid Solid Release Solid x1 Sec Hard reset Warning Against Executing a Hard Reset A hard reset will revert the flashed firmware back to its default factory settings Dependin...

Page 20: ...s of the starter before the engine starts and runs Do not turn off the remote start if this happens it is a normal programming operation 2 Once the engine begins running let it run for at least 30 sec...

Page 21: ...alteration improper installation mishandling misuse abuse neglect accident or by removal or defacement of the factory serial number bar code label s This Warranty is in lieu of all other express warra...

Page 22: ...k Press hold for 1 second to unlock Press hold for 1 second to remote start Press hold for 5 seconds to activate the trunk release optional Icon and remote appearance may differ depending on the model...

Page 23: ...om Directed the leader in vehicle security and remote start The simple graphical interface gives you control over the following features of your installed remote start or security with remote start sy...

Reviews: