Part 2 - Remote Setup
26
Remote Callback
Select
Remote Callback
to send callback messages to a
remote system.
• Not supported from the IDIS Web program.
• The encoder must be registered to the remote
system in order to use the
Remote Callback
feature.
•
IP Address
: Enter the IP address and port number of
the remote system that will receive the messages.
•
Retry
: Designate how many reattempts to make if
message delivery fails.
Event
Configure event detection settings.
Motion Detection
Select
Motion Detection
to configure motion detection
event settings. With motion detection event enabled,
motion detections within the designated area will be
assumed as events.
•
Camera Channels
: Select which cameras to apply the
motion detection to.
•
Sensitivity
: Select daytime and nighttime motion
detection sensitivity levels. Higher values will result in
more sensitive motion detection.
•
Minimum Blocks for Detection
: Select minimum
blocks for daytime and nighttime motion detection.
Motion must take place over the selected number
of blocks in order for it to be considered as a motion
detection event.
•
Motion Zone
: Click
Setup
and define the motion
zone using blocks.
-
(Select)/ (Unselect)
: Enable/disable motion
detection.
-
(Single Block)
: Select/unselect motion detection
blocks individually.
-
(Zone)
: Select/unselect multiple motion
detection blocks.
-
(All)
: Select/unselect all motion detection blocks.
•
Motion Ignoring Interval
: With Motion Ignoring
Interval configured, no event log or notification is
generated for motions detected during a period of
time following a motion detection event.
•
Daytime
: Specify when daytime starts and ends. All
other times will be assumed as nighttime.