GB
3. TECHNICAL DATA
Model
JE-600-P
Mains voltage / Frequency
(V / Hz)
220-240
Nominal performance (Watts)
600
Protection type (IP)
x4
Suction port
M26/34 (1")
Pressure port
M26/34 (1")
Max. flow rate (Qmax)
(1)
(l/h)
3 000
Max. pressure (bar)
3,5
Max. delivery height
(Hmax)
(1)
(m)
35
Max. suction height (m)
7
Max. size of the solids being
pumped (mm)
3
Min. ambient temperature (°C)
5
Max. ambient temperature (°C)
35
Min. fluid temperature (°C)
5
Max. fluid temperature
(Tmax) (°C)
35
Length of connection cable (m)
1,5
Cable type
H07RN-F
Weight (net) (kg)
6
Guaranteed sound power level
(LWA)
(2)
(dB)
80
Measured sound power level
(LWA)
(2)
(dB)
78,2
Dimensions (L x D x H) (mm)
375 x 225 x 241
1) The values were determined with free, unreduced in- an
outlet.
2) Noise emission values obtained according to the EN 12639
regulation. Measurement method according to EN ISO
3744.
4. SCOPE OF DELIVERY
The scope of the delivery of this product includes :
One pump with connection cable.
Please verify that the scope of delivery is complete.
Depending on the purpose of the application,
additional accessories may be necessary (please
refer to the chapters titled "Installation", "Automation
with special accessories”).
If possible, keep the packing until the warranty
period has expired. Please dispose of the packing
materials in an environmental-friendly manner.
5. INSTALLATION
5.1. GENERAL INSTALLATION INFORMATION
During the entire process of installation, the
device must not be connected to the
electrical mains.
The pump should be installed in a dry place
with an ambient temperature not to exceed
40 °C and not to fall below 5 °C. The pump
and the entire connection system have to be
protected from frost and other climatic influences.
When installing the device, please make
sure that the motor is sufficiently ventilated.
All connection lines have to be perfectly tight since
leaking lines may affect the performance of the
pump and cause considerable damage. Therefore,
please use Teflon tape to seal the contact surfaces
between the threaded sections of the lines and
the connection with the pump. This use of sealing
material such as Teflon tape is the only way to ensure
an airtight assembly.
When tightening threaded connections, please
do not apply excessive force which may cause
damage. When laying the connection pipes, you
should make sure that the pump is not exposed to
any form of weight, vibration or tension. Moreover,
the connection lines must not contain any kinks or
an adverse slope.
5.2. INSTALLATION OF THE SUCTION LINE
The intake of the suction line (1) has to be
equipped with a check valve (or non-return
valve) (2) and an intake filter (3A).
Please use a suction line having the same diameter as
the suction port (4) of the pump. If the suction height
(HA) exceeds 4 m, however, it is recommendable to
use a 25% larger diameter - including appropriate
reducer elements for the connectors.
The intake of the suction line has to be equipped
with a check valve (3B) - or non-return valve - and
an intake filter (2). The filter will keep away larger
dirt particles contained in the water which might
clog or even damage the piping. The check valve
will prevent the pressure to escape after the pump
has cut out. Moreover, it simplifies the venting of
the suction line by enabling water to be filled in. The
check valve with the intake filter - i.e. the entirety
of the intake section of the suction port - must be
immersed by at least 0.3 m below the surface of the
liquid to be pumped (HI). This will prevent air from
being taken in. In addition, please ensure a sufficient
distance of the suction line from both the ground and
the sides of water courses, rivers, ponds etc in order
to prevent stones, plants etc from being sucked in.