19.4 ANNUAL INSPECTION (REGULAR INSPECTION)
The inspection shall be performed by a skilled technician or an expert inspection body with
documented evidence of competence according to requirements presented under point
"Inspections" . In the inspection special attention has to be paid to the condition of the steel
structures, the safety devices and the operating system.
Clean the lift before the inspection
The inspection incorporates the following measures and checks:
–
perform the measures of the daily and monthly inspection
–
inspect thoroughly the hydraulic system
–
power unit
-
connect the pressure gauge to the measuring point in the hydraulic system
-
operate the "telescope in" movement at the speed-II at its end position to make
the oil flow through the relief valve
-
observe the pressure reading in the gauge; when the oil is warm the pressure
should be 21 – 21,5 MPa (210 – 215 bar)
–
load-holding check-valves on the outriggers
-
lift the device off the ground with the outriggers and measure the distance to
the chassis at each outrigger
-
step on the platform and extend the telescope keeping the boom level
Turn the boom round a few times, stop at the initial position and check that the
distance between the ground and the outriggers has not changed.
-
lift the outriggers from the ground and leave them in this position for about 10
minutes
Observe that the outriggers do not lower of themselves.
–
load-holding check-valve on the lift cylinder
-
lift the boom from the chassis control panel to an angle of about 45° and extend
the telescope
Observe about 10 minutes that the boom does not lower of itself.
–
load regulation valve of the telescope cylinder
-
lift the boom from the chassis control panel and extend the telescope slightly;
leave it in this position for about 5 minutes
-
make sure that the telescope does not retract of itself
–
load regulation valve of the levelling system
-
put a load of about 80 kg on the platform
-
lift and lower the boom 4 - 5 times
-
make sure that the position of the platform does not change
–
electric directional valves
-
operate all boom and turning movements and check that they all work properly
and that the movements stop as soon as the levers are released
Summary of Contents for Dino 95T
Page 2: ...DINO 95T 2...
Page 3: ...DINO 95T 3 ORIGINAL OPERATING INSTRUCTIONS Valid from serial number 95003...
Page 7: ...DINO 95T 7 2 REACH DIAGRAM...
Page 8: ...DINO 95T 8 3 DIMENSION DRAWING...
Page 39: ...DINO 95T 39 18 3 LUBRICATION PLAN...
Page 42: ...DINO 95T 42...
Page 53: ...DINO 95T 53 19 1 1 SAMPLE OF INSPECTION PROTOCOL FOR THE ACCESS PLATFORM...
Page 54: ...DINO 95T 54...
Page 69: ...DINO 95T 69 Notes...
Page 75: ...DINO 95T 75 24 ELECTRIC DIAGRAM 95T 95001...
Page 76: ...DINO 95T 76...
Page 77: ...DINO 95T 77...
Page 78: ...DINO 95T 78...
Page 79: ...DINO 95T 79...
Page 80: ...DINO 95T 80...
Page 81: ...DINO 95T 81...
Page 82: ...DINO 95T 82...
Page 83: ...DINO 95T 83...
Page 84: ...DINO 95T 84...
Page 85: ...DINO 95T 85 Notes...
Page 87: ...DINO 95T 87 26 HYDRAULIC DIAGRAM 95001...
Page 88: ...DINO 95T 88 Notes...