![Dino 210XT Operating Instructions Manual Download Page 74](http://html1.mh-extra.com/html/dino/210xt/210xt_operating-instructions-manual_2505759074.webp)
DINO 210XT
74
FAULT FINDING
FAULT REMEDY
1.
Electric motor does not start although the start button is pressed and the selector switch is
in position 1, 2 or 3
Emergency stop button is stuck.
Pull up the button and re-start the engine with
the start button.
Fuse F2 blown.
Replace the fuse (10A).
No mains supply (230 VAC) to the selector
switch.
Check the extension cords, possible distribution
boards and fuses.
The fault current safety switch has tripped.
Reset the fault current safety switch.
Voltage supply to the switch OK, but no
transmission forward.
Check the operation of the selector switch and
replace it, if necessary.
The power supply voltage both comes to the
selector switch and is fed further.
Check the operation of the engine control
contactor and thermo-relay as well as the
operation of the relays which control the
operation of the contactors.
Telescope chain limit switch RK7 has
disconnected the contactor circuit.
Check the operation of the RK 7 and readjust as
instructed in the picture on page 54.
No direct-current supply (12VDC).
Mains switch turned off, turn on the switch.
2.
None of the platform movements is operational though the electric motor is running and
the selector switch is in position 2 or 3
Green signal light for outriggers is not lit.
Check operation of the safety limit switches
RK11, RK12, RK13 and RK14.
The green signal light for the outrigger limit
switches is lit, but the boom movements do not
operate.
Check the operation of the safety relay SR2 for
the outrigger circuit.
Overloading of the boom has occurred.
Retract the platform with the buttons 6 or 21
inside the designated operating range of the
platform (the green light in the platform control
panel lights up).
3.
Outriggers do not move
Boom does not rest on the transport support.
Drive the boom onto the transport support.
The selector switch is in wrong position.
Turn the selector switch to position 1.
Limit switch on the boom support is not closed.
Drive the boom onto the transport support and
check the operation of the limit switch RK3.
4.
Platform turn is not operational
Automatic fuse F10 has tripped.
Reset the automatic fuse with the reset button.
Summary of Contents for 210XT
Page 2: ...DINO 210XT 2...
Page 3: ...DINO 210XT 3 OPERATING INSTRUCTIONS Valid from serial number 2945...
Page 6: ...DINO 210XT 6 REACH DIAGRAM...
Page 12: ...DINO 210XT 12...
Page 14: ...DINO 210XT 14...
Page 20: ...DINO 210XT 20 Notes...
Page 22: ...DINO 210XT 22...
Page 24: ...DINO 210XT 24...
Page 44: ...DINO 210XT 44 LUBRICATION PLAN...
Page 46: ...DINO 210XT 46 1...
Page 98: ...DINO 210XT 98 WIRING DIAGRAM...
Page 99: ...DINO 210XT 99 ELECTRIC DIAGRAM 2945...
Page 100: ...DINO 210XT 100...
Page 101: ...DINO 210XT 101...
Page 102: ...DINO 210XT 102...
Page 103: ...DINO 210XT 103...
Page 104: ...DINO 210XT 104...
Page 105: ...DINO 210XT 105...
Page 106: ...DINO 210XT 106...
Page 107: ...DINO 210XT 107...
Page 108: ...DINO 210XT 108...
Page 109: ...DINO 210XT 109...
Page 110: ...DINO 210XT 110...
Page 111: ...DINO 210XT 111...
Page 112: ...DINO 210XT 112...
Page 113: ...DINO 210XT 113...
Page 114: ...DINO 210XT 114...
Page 115: ...DINO 210XT 115...
Page 116: ...DINO 210XT 116 Notes...
Page 118: ...DINO 210XT 118 HYDRAULIC DIAGRAM 2945...
Page 119: ...DINO 210XT 119 Notes...