SET/EVNT/STRT Selection Summary
STRT Event starts when
Value
to set
0
Always starts
-
1
Time > setting (0.0-23.9)
TIME
2
Solar panel voltage
(open circuit) > setting #
SOLV
3
Solar panel voltage
(open circuit) < setting #
SOLV
4
External voltage
VEXT * > setting
VEXT
5
External voltage
VEXT * < setting
VEXT
6
PB** is on and time > setting
TIME
7
PB** is off and time > setting
TIME
8
Repeat start at 10 min intervals
if time > setting
TIME
9
Repeat start at 30 min intervals
if time > setting
TIME
10
Repeat start at 1hr intervals if
time > setting
TIME
11
Repeat start at 2hr intervals if
time > setting
TIME
12
Battery voltage > setting
VBAT
13
Battery voltage < setting
VBAT
14
Repeat start at a set rate
(0-240 min)
RATE
15
Repeat start at a set rate
(0.0-24.0h)
RATE
#Note: After up to 1 min delay if the solar charge
switch has not turned off.
* Note: The user can select where VEXT is
measured. If BSET is set to 2, then VEXT is the
voltage measured by the B+ sense input (relative
to BAT+ in the negative direction). The maximum
VEXT measurable this way is 27V. If BSET is not 2,
then VEXT can be measured by a bus accessory,
**Note: “PB” means a push-button switch. If you
wish to use this option, you can wire a switch or
other contact closure device between the B+ sense
terminal (green terminal block) and the BAT+
terminal, and select BSET = 2.
Step 4
Select a STOP setting in this table to tell the
Dingo what signifies the end of the “event”. After
setting the STOP value, a short-push will move
you to the associated setting. For example, if you
set STOP to ‘1’, you will see ‘TIME’.
Once started, the “event” will then continue
until the time reaches the time you specify in
the TIME setting. To allow events which go past
midnight, there are special rules for STOP=1.
SET/EVNT/STOP Selection Summary
STOP Event stops when
Value
to set
0
Stop never active
-
1
Time > setting (0.0-25.2)
TIME
2
Solar panel open circuit voltage
> setting #
SOLV
3
Solar panel open circuit voltage
< setting #
SOLV
4
External voltage VEXT *
> setting
VEXT
5
External voltage VEXT *
< setting
VEXT
6
PB** on and time > setting
TIME
7
PB** off and time > setting
TIME
8
Repeat stop at 1 min intervals if
time > setting
TIME
9
Repeat stop at 3 min intervals if
time > setting
TIME
10
Repeat stop at 6 min intervals if
time > setting
TIME
11
Repeat stop at 12 min intervals
if time > setting
TIME
12
Battery voltage > setting
VBAT
13
Battery voltage < setting
VBAT
14
Stop after a set run time
(0-240min)
RUN
15
Stop after a set run time
(0.0-24.0h)
RUN
#Note: After up to 1 min delay.
*Note: “VEXT” has the same meanings as in the
STRT table.
**Note: “PB” has the same meanings as in the
STRT table.