Firmware Version 143 ff. Rev 1.39 03.10.17
Dingo 4040P Reference Manual
22
7.5 MODE Menu (Adjusting Configuration Settings) [PROG=4 only]
LSET
GSET
ESET
BSET
BAT2
PWM
BCAP
ALRM
RSET
DFLT
BATV
CHRG
LOAD
IN
OUT
DATA
SET
TIME VOLT PROG REG
MODE
EVNT
Set function of LOAD terminal
Set function of general purpose terminal (G)
Set control of external switches
Set function of B input
Set Regulation voltage for 2nd battery control
Set which terminals use Pulse width Modulation
Set amp Hour capacity of the battery (20-20,000AH)
Set voltage at which to activate alarm
Reset system (losing today’s data and time)
Reload factory default settings
Fig. 7.5A - MODE Menu
The MODE submenu contains most of the
settings for the configuration of the Dingo other
than the main regulation settings.
7.5.1 LSET & GSET Controlling the
load and G outputs
There are two output terminals on the Dingo
(LOAD and “G”) and six logical control functions.
The LSET and GSET settings define which of
the six functions controls each of these output
terminals.
Note that the settings described below are different
from the LSET and GSET screens described in
Section 2 and 3.
The six internal control functions are:
a. Low battery disconnect. This also controls
the “LOAD” indicator at the bottom of the
screen.
b. Run the backup generator. This also controls
the “GEN” indicator at the bottom of the
screen.
c. Charge a second battery. Indicates when the
solar input can be diverted to a 2nd battery.
d. Battery voltage alarm output. Provides an
output based on the battery voltage.
SET/MODE Selection Summary:
Name Description
Range
LSET
Select the control of
the LOAD switch
0-11
GSET Select the control of
the “G” relay
0-11
ESET
Select the control for
external switchblocks
see 7.5.2
BSET Select the use of the
B- sense input
0-3
BAT2 Regulation voltage for
2nd battery control
13.0-16.0V
PWM Select which terminals
use PWM (SOL, LOAD)
0-3
BCAP Amp hour capacity of
the battery bank
20-20,000Ah
ALRM Alarm voltage
10.0-18.0V
RSET Resets the controller (warm reboot).
Clears day data and time
DFLT Resets Prog 4 settings to Prog 1 settings.
Used to reset factory default settings.
e. Shunt regulation. Gives an output useful for
regulation by dumping the input energy.
f. Event controller. An output which is active
when a specified set of conditions occurs.
7