23
measuring temperature
F After adjustment, you should fix the detector, avoid the detector from
impacting the machine measuring temperature when shaking
G Adjustment method in this example only apply to the state that when
these two curves move in parallel and uniform deviation, useless when
temperature up and down in disorder
H Location of galvanic couple inside the upper blow-dryer: take down the
blow-dryer, cover in the couple 2-3cm away from the blow-dryer
I Please according to relevant correct operation; avoid to be burnt by high
temperature!
8
Use the same theory, paste the outer galvanic couple on the bottom of PCB
board, that is the right above of bottom dryer, only reserve lower heating
(turn off the upper heating), can measure and correct the accuracy of
lower heater
9 Statement: Turn off the upper heater (set the data relevant to upper heater to
be 0) (Remark: This machine take the upper heating time as benchmark to
set other segments, so when start lower heating alone, set the upper
temperature to be 0, first segment of upper constant time should be set to
larger than or equal to total lower heating time)
10 Matters to be attention please refer above 7th relevant details
11 Adjusting methods in details are as below:
A If the electric dipole measuring curve (light blue) is lower than actual temperature
curve (green), can adjust Electric dipole probe in the hair dryer to downward
B If the electric dipole measuring curve (light blue) is higher than actual temperature
curve (green), can adjust Electric dipole probe in the hair dryer to upward