17
1. Camera: The indicator will turn green when CCD Camera in the oringal.
2. Suction: The indicator is on green, the top heater is on stand by.
3. Protect: The indicator is on green, when the top heater inductive switch in on.
4. Limit: The indicator is on green, when the top heater goes to the bottom.
5. Origin: The indicator is on green, when the top heater is on the default position.
6. Soldering position: Welding position can be setting here.
7. Location: Showing the present position of the top heater.
8. Optics position: Showing the present position of the top heater.
9. Speed: showing the speed of the top heater, can setting from 3-7
10.Low speed, only can set from 1-3
11.Cooling time: cooling time, you can set to what you need,we usally set 200seconds
12. Reset: Click it, the top heater will go back to back to the top.
13. Vacuum: Click it, the vacuum will on working.
14. Manual Up: Click it, the top heater will goes up
15. Manual Down: Click it, the top heater will goes down
16.Change speed: it is for changing the speed from low speed to high speed.
Attention:
When it alarm because of stoppage, all function buttons are in locked state! After