DinLOG – User Manual
Page | 15
Rev 1.6
3.1.2.2. Maintenance mode (with menu overview)
To change the system’s operating parameters, maintenance mode needs to be accessed.
Maintenance mode is entered by simultaneously pressing all 3 top row buttons for 2 sec. If maintenance
mode is accessed successfully, message UNLOCKED is shown on the screen.
To exit maintenance mode simultaneously press 3 top row buttons for 2 sec. Message LOCKED will be
displayed on the screen.
Current filter temperature
Current filter back pressure
800 rpm
off
Current engine speed
Setup menu, system parameters
Table 3.3.
Maintenance mode menu
Maintenance mode is scrolled through using the (+) and (-) buttons, and each sub-menu is accessed using
the
button. Maintenance sub-menus are described in the following section.
3.1.3. Logger configuration (maintenance mode)
3.1.3.1. Temperature settings
While in maintenance mode of the OnRoad device, temperature settings can be accessed within the main
menu using the
button. Inside this menu the user can set lower and upper temperature limits.
While displaying current temperature, press
to edit
Lower temperature limit, press
to edit
E: T(U)= 750
˚C
Upper temperature limit, press
to edit
Exit menu, press
to exit
Table 3.4.
Temperature settings menu
91
˚
C
76 mbar
SETUP
91
˚
C
T(L): 70
˚C
E: T(L)= 70
˚C
T(U): 750
˚C