13 Device Information
1
Type and order code
WI 9TE
WI 14TE
WI 18TE
WI 22TE
WI 27TE
2
Design
2.1
Degree of protection according to EN 60 529
IP 20
IP 20
IP 20
IP 20
IP20
2.2
Installation Location
Indoors
Indoors
Indoors
Indoors
Indoors
3
Performance data
3.1
Operating temperature limits:
Heating water flow
°C
Up to 58
Up to 58
Up to 58
Up to 58
Up to 58
Cold water (heat source)
° C
+7 to +25
+7 to +25
+7 to +25
+7 to +25
+7 to +25
3.2
Temperature spread of heating waterat W10 / W35
K
9.5
5.0
8.8
5.0
9.2
5.0
9.6
5.0
9.4
5.0
3.3
Heat output / COP
at W7 / W55
1
kW / ---
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. W10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
6.9 /
2.5
12.2 /
2.5
14.9 /
3.0
19.0 /
3.2
24.6 /
3.2
at W10 / W50
1
kW / ---
7.7 /
3.2
13.4 /
3.6
16.3 /
3.7
20.8 /
3.8
26.4 /
3.8
at W10 / W45
1
kW / ---
7.6 /
3.5
13.2 /
3.8
16.1 /
4.0
20.5 /
4.0
26.0 /
4.1
at W10 / W35
1
kW / ---
8.3 /
5.1
8.2 /
4.9
13.6 /
5.2
13.5 /
5.0
17.1 /
5.3
16.9 /
5.2
21.5 /
5.5
21.3 /
5.3
26.4 /
5.1
26.1 /
4.9
3.4
Sound power level
dB(A)
53
55
55
58
59
3.5
Heating water flow with an internal pressure differential of m³/h / Pa
0.75 /
7000
1.4 /
24000
1.3 /
7000
2.3 /
22000
1.6 /
2600
2.8 /
7600
2.0 /
8000
3.7 /
24300
2.4 /
12500
4.5 /
36000
3.6
Cold water flow rate at an internal pressure differential of
(heat source)
m³/h / Pa
2.0 /
6200
1.9 /
5600
3.3 /
19000
3.2 /
13000
4.0 /
12000
3.6 /
9500
5.0 /
20000
4.8 /
17900
7.0 /
16000
6.7 /
14900
3.7
Refrigerant; total filling weight
type / kg
R407C / 1.7
R407C / 1.9
R407C / 3.5
R407C / 3.2
R407C / 4.5
3.8
Lubricant; total filling weight
type / litres
Polyolester
(POE) / 1.0
Polyolester
(POE) / 1.36
FV68S / 1.7
Polyolester
(POE) / 1.77
Polyolester
(POE) / 4.1
4
Dimensions, connections and weight
4.1
Device dimensions without connections
2
H x W x L mm
2. Note that additional space is required for pipe connections, operation and maintenance.
1445 x 650 x
575
1445 x 650 x
575
1445 x 650 x
575
1445 x 650 x
575
1445 x 650 x
575
4.2
Device connections to heating system
Inch
G 1¼" exter-
nal
G 1¼" exter-
nal
G 1¼" exter-
nal
G 1¼" exter-
nal
G 1¼" exter-
nal
4.3
Device connections to heat source
Inch
G 1¼" exter-
nal
G 1¼" exter-
nal
G 1½" exter-
nal
G 1½" exter-
nal
G 1½" exter-
nal
4.4
Weight of the transportable unit(s) incl. packing
kg
156
168
187
189
259
5
Electrical Connection
5.1
Nominal voltage; fuse protection
V / A
400 / 16
400 / 16
400 / 16
400 / 20
400 / 20
5.2
Nominal power consumption
1
W10 W35
kW
1.62
1.68
2.64
2.72
3.21
3.27
3.93
4.02
5.15
5.29
5.3
Starting current with soft starter
A
30 (without
SS)
26
28
27
29
5.4
Nominal current W10 W35 / cos
A / ---
2.9 /
0.8
3.03 /
0.8
4.8 /
0.8
4.91 /
0.8
5.8 /
0.8
5.90 /
0.8
7.0 /
0.8
7.25 /
0.8
9.4 /
0.8
9.54 /
0.8
6
Complies with the European safety regulations
3
3. See CE declaration of conformity
3
3
3
3
7
Additional model features
7.1
Water in device protected against freezing
4
4. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes
Yes
Yes
Yes
Yes
7.2
Performance levels
1
1
1
1
1
7.3
Controller internal/external
Internal
Internal
Internal
Internal
Internal