18
Circuit diagram legend
A1/Z1, A2/Z2 - Control signal AC charge control
K1
- Heating contactor
L1, L2, L3
- External conductors
LE
- Fan control
LH
- Supplementary heating control
M1
- Fan motor
N
- Neutral conductor
PE
- Protective conductor
R1-R3
- Heating elements
R7
- Series resistor for fan (not all types)
R8
- Control resistors (charging)
R9
- Supplementary heating (accessories)
RTR
- Room temperature controller (accessories)
STR1, STR2 - Safety temperature controller
TB
- Temperature limiter
TR
- Charge controller
TR9
- Supplementary heating temperature
controller
TRG
- Ventilation grid temperature controller
Electrical Connection
English
Please observe your local technical connection requirements.
With a fixed connection thermust be an all-pole head release devise connected in series with at least 3 mm clearance between
it and the device. This requirement is met with circuit breakers for example.
For start-up see the following page.
Reinsert the front and side panels and fasten the screws. Reverse dismounting procedure.
15. Carry out the electrical connection to the terminal strip of the device.
Connection example: With heating contactor and wall-mounted thermostat.