Set digits 2, 3 and 4 of the number code in the
same way.
Press the ENTER key. The functions runback timer
(rb) and minimum/maximum temperature (SP) are
locked.
Confirm the BACK key to return to the standard
display.
11.6 Window monitoring
The room heating device is equipped with a monitoring
function that detects whether unnecessary energy is
being consumed due to an open window. In this case,
the heating device reduces the heat output. The
WINDOW MONITORING function is activated at the
factory.
The controller may read sudden temperature
decreases in drafty or poor insulated environments as
well as if the heater is undersized for the room.
In this case the feature should be disabled.
This function can be activated or deactivated as
follows:
Press and hold the MENU key and the FORWARD
key for five seconds.
rb display flashes.
Press
or
to select the WINDOW symbol. The
symbol flashes.
Press the ENTER key. The ON symbol flashes.
Press
or
to select the ON or OFF symbol.
The symbol flashes.
Press the ENTER key.
Confirm the BACK key to return to the standard
display.
11.7 Reset to factory settings
Resets all settings made by the user to the pre-set
factory settings.
Press and hold the
and
keys for five
seconds. INFO display flashes.
Press
or
to select the Fr display. The symbol
flashes.
Press the ENTER key. Display N (= no) flashes.
Press
or
to select the Y display. The symbol
flashes.
Press the ENTER key. All values are reset to
factory settings.
Set the time and date.