background image

24

Advanced Settings

These settings can be used to significantly change the operation of the heater. While useful for very specific 
requirements, there is a much higher risk of User error and unintended consequences of changing these settings 
compared to the top-level settings menu. It is recommended that these settings are only modified by trained 
professionals.

To navigate to the Advanced settings menu, from the home screen: 

Press and hold 

Advance

 and 

Menu 

buttons for 5 seconds.

Each of the following headings relate to an item in the settings menu.

Temperature Settings 

Temp Units (Temperature Units)
This setting defines which temperature units are displayed on the heater. The default is °C, but °F can be set. When 
°F is selected, the heater will covert °C values to °F and round to the nearest number.

Service Settings

Room Temp (Temperature) Offset
• 

Panels and Storage Heaters

• 

Service personnel use only.

• 

Allows the manual adjustment of electronic thermostat reading by +/-0.2°C

Factory Reset

This setting allows the User to restore the default values to all settings. Returning the product to the same state 
that it left the factory.

Summary of Contents for PLX050E

Page 1: ...INSTRUCTION MANUAL Installation and Operating 08 54284 0 ISSUE 1 Series B PLXE Panel Heater Models PLX050E PLX075E PLX100E PLX125E PLX150E PLX200E PLXC300E Note PLXC300E features a slotted grille...

Page 2: ...top of the heater or the air inlet slots in the base of the heater The heater carries a warning DO NOT COVER to alert the user to the risk of fire that exists if the heater is accidentally covered CAU...

Page 3: ...s mains lead are coloured in accordance with the following code GREEN AND YELLOW EARTH BLUE NEUTRAL BROWN LIVE The heater is fitted with a length of flexible cable type H05VV F size 3 x 1 0mm2 for con...

Page 4: ...I E E Wiring Regulations Please note that lit cigarettes candles and oil burners combined with the convection effect of electric heaters can cause soot deposits to build up on the surface directly abo...

Page 5: ...4...

Page 6: ...W 0 75kW 1 00kW 1 25kW 1 50kW 2 00kW 3 00kW Auxiliary electricity consumption At nominal heat output elmax 0 00 0 00 0 00 0 00 0 00 0 00 0 00 At minimum heat output elmin 0 00 0 00 0 00 0 00 0 00 0 00...

Page 7: ...powder coated steel casing with louvered forward facing grille Advanced controls with capacitive sense technology for total flexibility of heating Note PLXC300E features a slotted grille Element Compa...

Page 8: ...hat stated on the heater General Wall Mounting IMPORTANT The wall bracket supplied with the heater must be used and the heater must be installed in the correct orientation The fixings should be used t...

Page 9: ...type 3 Present the heater to the wall bracket and engage bottom slots in the back with bracket hooks 4 Press heater into locked position and ensure the clips on the top are engaged 5 Remove protectiv...

Page 10: ...he Heaters controls refer to page 11 The Heater will then take the User to the Home Screen with the Out All Day Timer Mode active First Time Power On Important During initial heat up some odour may be...

Page 11: ...mplex Control on your device s app store Requires additional hardware Sold seperately Visit Dimplex co uk for more information A Dimplex Hub is required for this product to connect to Dimplex Control...

Page 12: ...perature and is normal for this type of product Whilst the noise produced is usually very quiet certain environmental factors can make it more noticeable such as hard flooring or minimal furnishings I...

Page 13: ...isplayed in a manual mode of operation When the controller buttons have not been pressed for a long period of time the display will sleep and the text will disappear The heater is still on and active...

Page 14: ...et Temperature of a Heating On period when that period is active This will temporarily adjust the Target Temperature for just that instance and will not permanently modify the settings for the timer i...

Page 15: ...Preview This option displays the timer s configuration This is handy to quickly check the timer without being able to change any values ADVANCE MENU BACK ENTER Manual 21 C Period 1 Period 2 Period 3 P...

Page 16: ...py Paste To save time when modifying a Timer Mode the Advance button can be used to copy and paste settings Individual heating periods from one day or every heating period from a day can be copied to...

Page 17: ...and no date is set Away Mode will count from either the current time or if a date is set Away Mode The Advance button is only used when a Timer Mode is active and allows the timer schedule to be chan...

Page 18: ...Temperature value Manual Default 21 C Can be changed from the Home Screen to any value within the Heater s Temperature Range Eco Default 19 C Can be changed from the Home Screen to any value in the H...

Page 19: ...s Target Temperature Range setting The Boost Time can be increased in the following increments 30 mins 1 hour 2 hours 3 hours 4 hours These increments can be restricted with the Max Boost Duration Ran...

Page 20: ...choose to unlock the heater if they wish to change the temperature modes or settings Heater Lock PIN Lock Heater Lock is the most customisable and secure lock on the heater This allows the heater to...

Page 21: ...Disabled during UI lock the Advance button will not function Boost Function Operation during PIN Lock If enabled Boost will function in the same way as it does when PIN Lock is not active unless modi...

Page 22: ...ell as enable disable modification of the Boost Temperature and Boost Duration See below Boost Lock Three settings can be modified within this Menu Enable Disable The Boost Menu Item can be Enabled Di...

Page 23: ...boost is activated Boost Settings Setback Settings Setback is a function that only modifies Timer Mode operation When Setback is enabled it overrides any Heating Off period to maintain a constant tem...

Page 24: ...n This is a global setting that can interrupt any active mode Activating this setting enables Open Window Detection to switch the Heater to a Heating Off state if it detects an open window in the room...

Page 25: ...ttons for 5 seconds Each of the following headings relate to an item in the settings menu Temperature Settings Temp Units Temperature Units This setting defines which temperature units are displayed o...

Page 26: ...t Code Description 20 Component thermistor hardware fault 21 22 23 24 30 Component overheat 32 33 34 40 Internal serial comms error 41 Heating element fault 50 Open window detected 52 Heat output disa...

Page 27: ...26...

Page 28: ...ig 2 page 7 and locate the battery module 2 Slide the catch and pull module from the controls 3 Remove the coin cell battery and replace 4 Slide module back in place ensuring clip is engaged IMPORTANT...

Page 29: ...om the wall using the clips shown in Fig 2 page 7 and locate the battery module indicated in Fig 5 2 Slide the catch and pull module from the controls See Fig 5 1 3 3 Replace the tray with the radio f...

Page 30: ...by this Dimplex Guarantee there may be a charge to repair your product However we will contact you for agreement to any charges before any chargeable service is carried out What is not covered by a Di...

Page 31: ...art the two year Guarantee Period afresh from the date of delivery of the replacement Dimplex product to you The Dimplex Guarantee does not entitle you to recovery of any indirect or consequential los...

Page 32: ...h the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 9...

Reviews: