background image

www.dimplex.de

A-XI

An

hang

 · 

Ap

pend

ix

 · 

An

nex

e

s

3.6

3.6

Legende / Legend / Légende

A1

Drahtbrücke einlegen wenn kein Sperrschütz benö-
tigt wird (Brücke offen = EVU-Sperre = WP „aus“)

Insert wire jumper if no blocking contactor is 
required (bridge open = utility block = HP “off”)

Cavalier à fil à insérer en absence de disjoncteur de 
blocage du fournisseur d'énergie (pont ouvert = blo-
cage société électricité = PAC « arrêt »)

A2

Drahtbrücke bei Nutzung des 2ten Sperreinganges 
entfernen (Brücke offen = EVU-Sperre = WP „aus“)

Remove wire jumper if disable contactor 2 is used 
(bridge open = utility block = HP “off”)

Cavalier à fil à retirer si la 2e entrée de coupure est 
utilisée (pont ouvert = blocage société électricité = 
PAC « arrêt »)

A4

Drahtbrücke (immer eingelegt; Eingang wird bei 
Luft-Wasser-Wärmepumpen nicht genutzt)

Wire jumper (always inserted; input is not used for 
air-to-water heat pumps)

Cavalier à fil (toujours inséré ; l’entrée n’est pas uti-
lisée pour des pompes à chaleur air/eau)

B3*

Thermostat Warmwasser

Hot water thermostat

Thermostat eau chaude

B4*

Thermostat Schwimmbadwasser

Swimming pool water thermostat

Thermostat eau de piscine

C1

Betriebskondensator Verdichter

Running capacitor, compressor

Condensateur de service - compresseur

C3

Betriebskondensator Ventilator

Running capacitor, fan

Condensateur de service - ventilateur

E3

Pressostat Abtauende

Defrost end controller

Pressostat fin de dégivrage

E9

Elekt. Tauchheizkörper Warmwasser

Electric immersion heater, hot water

Thermoplongeur électr. eau chaude

E10

2. Wärmeerzeuger Elektroheizung (Funktion ist 
über Regler wählbar)

2nd heat generator, electric heating (function 
selectable via controller)

2e générateur de chaleur chauffage électrique 
(fonction réglable par le régulateur)

E13*

2. Kälteerzeuger

Chiller 2

2. générateur de froid

F2

Sicherung für N1-Relaisausgänge an J12 und J13
4,0 ATr

Fuse for N1 relay outputs at J12 and J13
4.0 slow-acting

Fusible pour sorties de relais N1 en J12 et J13
4,0 ATr

F3

Sicherung für N1-Relaisausgänge an J15 bis J18
4,0 ATr

Fuse for N1 relay outputs at J15 to J18
4.0 slow-acting

Fusible pour sorties de relais N1 en J15 jusqu’à J18
4,0 ATr

F4

Pressostat Hochdruck

High-pressure switch

Pressostat haute pression

F5

Pressostat Niederdruck

Low-pressure switch

Pressostat basse pression

F7

Heißgasthermostat

Hot gas thermostat

Thermostat gaz de chauffage

F23

Wicklungsschutz Ventilator

Winding protection, ventilator

Blindage de l'enroulement ventilateur

H5*

Leuchte Störfernanzeige

Remote fault indicator lamp

Témoin de télédétection de pannes

N1:

J1

Stromversorgung-N1 (24VAC)

Power supply N1 (24 V AC)

Alimentation en courant N1 (24 V AC)

J2...J3

Sensoreingänge

Sensor inputs

Entrées de capteurs

J4

Analogausgänge, werden nicht genutzt

Analogue outputs are not used

Sorties analogiques libres

J7...J8

Digitaleingänge

Digital inputs

Entrées numériques

J9

Ohne Funktion

Has no function

Sans fonction

J10

Steckdose für Fernbedienung

Socket for remote control 

Prise pour la télécommande

J11

pLAN-Anschluss

Connection for pLAN

Connexion pLAN

J12

Relaisausgänge für Verdichter und Ventilator

Relay outputs for compressor and ventilator

Sorties de relais pour compresseur et ventilateur

J13...J18 Relaisausgänge zur Ansteuerung der Systemkom-

ponenten (230 VAC)

Relay outputs for controlling system components 
(230 V AC)

Sorties de relais pour la commande des compo-
sants du système (230 V AC)

N2:

J1

Stromversorgung-N2 (24VAC)

Power supply N2 (24 V AC)

Alimentation en courant N2 (24 V AC)

J2...J3

Sensoreingänge

Sensor inputs

Entrées de capteurs

J4

Analogausgänge, werden nicht genutzt

Analogue outputs are not used

Sorties analogiques libres

J5

Digitaleingänge

Digital inputs

Entrées numériques

J9

Ohne Funktion

Has no function

Sans fonction

J10

Steckdose für Fernbedienung

Socket for remote control 

Prise pour la télécommande

J11

pLAN-Anschluss

Connection for pLAN

Connexion pLAN

J12

Relaisausgänge für M14, M19 und H5 (230 VAC)

Relay outputs for M14, M19 and H5 (230 V AC)

Sorties de relais pour M14, M19 et H5 (230 V AC)

J13...J18 Relaisausgänge zur Ansteuerung der Systemkom-

ponenten (230 VAC)

Relay outputs for controlling system components 
(230 V AC)

Sorties de relais pour la commande des compo-
sants du système (230 V AC)

K2

Schütz Ventilator

Contactor for ventilator

Contacteur ventilateur

K11*

Elektron. Relais f. Störfernanzeige (Relaisbau-
gruppe)

Electron. remote fault indicator relay (relay module)

Relais pour télédétection de pannes (sur module de 
relais)

K12*

Elektron. Relais f. Schwimmbadwasserumwälz-
pumpe (Relaisbaugruppe)

Electron. relay for swimming pool water circulating 
pump (relay module)

Relais pour circulateur d’eau de piscine (sur 
module de relais)

K20

Relais 2. Wärmeerzeuger

Relay, back-up heater

Relais chauffage complémentaire

K21*

Schütz Elekt. Tauchheizkörper Warmwasse

Contactor electric immersion heater, hot water

Contacteur, thermoplongeur électr. eau chaude

K22*

EVU-Sperrschütz

Utility blocking contactor

Contacteur de coupure du fournisseur d'énergie

K23*

SPR-Hilfsrelais

SPR auxiliary relay

Relais auxiliaire « SPR »

K25

Startrelais für N7

Starting relay for N7

Relais de démarrage pour N7

K28*

Anforderung Kühlbetrieb

Cooling operation request

Demande mode rafraîchissement

M1

Verdichter

Compressor

Compresseur

M2

Ventilator

Ventilator

Ventilateur

M13*

Heizungsumwälzpumpe Heat 

circulating pump 

Circulateur de chauffage

M14*

Heizungsumwälzpumpe 1. Heizkreis

Heat circulating pump of heating circuit 1

Circulateur de chauffage 1er circuit de chauffage

M15*

Heizungsumwälzpumpe 2. Heizkreis

Heat circulating pump for heating circuit 2

Circulateur de chauffage 2e circuit de chauffage

M16*

Zusatzumwälzpumpe

Auxiliary circulating pump

Circulateur supplémentaire

M18*

Warmwasserumwälzpumpe

Hot water circulating pump

Circulateur d’eau chaude

M19*

Schwimmbadwasserumwälzpumpe

Swimming pool water circulating pump

Circulateur d’eau de piscine

M21*

Mischer Hauptkreis

Mixer for main circuit

Mélangeur circuit principal

M22*

Mischer 2. Heizkreis

Mixer for heating circuit 2

Mélangeur 2e circuit de chauffage

N1

Wärmepumpenregler

Heat pump controller

Régulateur de pompe à chaleur

N2

Kühlregler

Cooling controller Régulateur 

refroidissement

N3/N4*

Raumstationen

Room stations

Stations de pièce

N5*

Taupunktschalter

Dew point switch

Interrupteur du point de condensation

N7

Sanftanlaufsteuerung

Soft start control

Commande de démarrage progressif

N9*

Raumtemperaturregler

Room temperature controller

Régulateur de température ambiante

N11*

Relaisbaugruppe

Relay module

Module de relais

N14

Bedienteil

Operating element

Commande

Summary of Contents for LIK 8MER

Page 1: ...at Pump for Indoor Installation Pompe à chaleur air eau réversible pour installation intérieure Montage und Gebrauchsanweisung Deutsch English Français Instructions d installation et d utilisation Installation and Operating Instructions Bestell Nr Order no No de commande 452160 66 23 FD 8611 ...

Page 2: ...ansport E 4 5 Set UP E 5 5 1 General Information E 5 5 2 Condensed Water Pipe E 5 5 3 Sound E 5 6 Installation E 5 6 1 General Information E 5 6 2 Air Connection E 5 6 3 Heating System Connection E 6 6 4 Electrical Connection E 6 7 Start UP E 7 7 1 General Information E 7 7 2 Preparation E 7 7 3 Start Up Procedure E 7 8 Maintenance Cleaning E 8 8 1 Maintenance E 8 8 2 Cleaning the Heating System E...

Page 3: ...apable of operating the device safely due to their physical sensory or mental abilities or their inexperience or lack of knowledge must not operate this device without supervision or instruction by the person in charge Children must be supervised to ensure that they do not play with the device 1 3 Energy Efficient Use of the Heat Pump With the purchase of this heat pump you are helping to protect ...

Page 4: ...transferred to the heating water using the liquifier heat ex changer Electrical energy is used to raise the temperature of the heat in the environment to a higher level Because the energy extracted from the air is transferred to the heating water this type of device is called an air to water heat pump The air to water heat pump consists of the main components evaporator ventilator and expansion va...

Page 5: ...2 Sealing rings for duct connection 3 1 connecting hoses 3 1 double nipples 6 1 flat gaskets 1 1 sealing plug 1 Hose nozzle for filling and drain cock 2 Fixing brackets 2 10 mm dowels 2 8 x 80 screws 4 M4 x 8 screws 1 External sensor 1 6 mm dowels 1 4 5 x 50 screws 4 Transport ATTENTION When transporting the heat pump ensure that it is not tilted more than 45 in any direction Use a wooden pallet f...

Page 6: ...o prevent solid borne sound from being transmitted to the heat ing system a vibration damped connection should be used for connecting the heat pump with the heating system install the supplied hose connections free of strain Installed air ducts should be sound isolated from the heat pump to prevent the transmission of solid borne sound to the ducts If both air openings are connected directly to a ...

Page 7: ...be filled de aerated and pressure tested The integrated expansion vessel has a volume of 24 litres This volume is suitable for buildings with a living space area to be heated of maximum 200 m The volume should be checked by the heating system engineer If necessary an additional expansion vessel must be installed according to DIN 4751 Part 1 The tables listed in the manufac turers catalogues simpli...

Page 8: ... and west sides of the building At least one heating circuit must remain open e g bathroom The overflow valve should be opened far enough to produce the maximum temperature spread between the heating flow and re turn flow listed in the following table for the current heat source temperature The temperature spread should be measured as close as possible to the heat pump The heating element of mono ...

Page 9: ...from entering the heating sys tem circuit we recommend connecting the flushing device di rectly to the flow and return flow of the liquifier of the heat pump It is important that the system be thoroughly flushed using appro priate neutralising agents to prevent any damage from being caused by cleaning agent residue remaining in the system Acids must be used with great care and all relevant regulat...

Page 10: ...eating water flow with an internal pressure differential of 2 m h Pa 2 The heat circulating pump is integrated 0 8 2700 1 6 11900 3 9 Free pressure heating circulating pump heating max stage Pa 45000 27000 3 10 Cooling water flow with an internal pressure differential of m h Pa 0 8 2700 1 2 6500 3 11 Free pressure circulating pump cooling max stage Pa 45000 37000 3 12 Air flow rate with an externa...

Page 11: ...roller Commande régulateur standard A VI 3 2 Steuerung Kühlregler Control of the cooling controller Commande régulateur standard A VII 3 3 Last Load Charge A VIII 3 4 Anschlussplan Standardregler Terminal diagram for the standard controller Schéma électrique du régulateur standard A IX 3 5 Anschlussplan Kühlregler Terminal diagram for the cooling controller Schéma électrique du régulateur refroidi...

Page 12: ...DJH LQWpULHXU H WpULHXU 5HIOX FRPPXQ QWUpH GDQV OD 3 LOHWDJHV LQW H W 5RELQHW GH UHPSOLVVDJH HW GH YLGDJH pSDUW HDX FKDXGH 6RUWLH GH OD 3 LOHWDJH LQW H W DVVHU DQVFKO VVH DWHU FRQQHFWLRQV 5DFFRUGHPHQWV HDX RQGHQVDWDEODXI VFKODXFK RQGHQVDWH RXWIORZ KRVH 7X DX HDX GH FRQGHQVDWLRQ XIWULFKWXQJ LUHFWLRQ RI DLU IORZ 6HQV G pFRXOHPHQW DLU HGLHQVHLWH 2SHUDWLQJ VLGH Wp GH FRPPDQGH QQHQJHZLQGH 0 LQWHUQDO WK...

Page 13: ...Q DFFHVVRU RQGXLW G DpUDWLRQ GLVSRQLEOH HQ DFFHVVRLUH 8PODXIHQGH EVFKUlJXQJ EDXVHLWV XU EGLFKWXQJ GHU 6WR NDQWH XQG 9HUEHVVHUXQJ GHU XIWI KUXQJ RQWLQXRXV FKDPIHU WR EH SURYLGHG E WKH FXVWRPHU WR VHDO WKH ERUGHU DQG WR IDFLOLWDWH DLU FLUFXODWLRQ KDQIUHLQ SpULSKpULTXH j IRXUQLU SDU OH FOLHQW DVVXUDQW O pWDQFKpLWp GX ERUG HW DPpOLRUDQW OD FRQGXLWH GH O DLU HL LQVDW HLQHV lPPVWUHLIHQV XQWHU GHU lUPHSX...

Page 14: ...Q 3D 3HUWH GH SUHVVLRQ HQ 3D HLVWXQJV DKO LQFO 3XPSHQOHLVWXQJVDQWHLO RHIILFLHQW RI SHUIRUPDQFH LQFO SRZHU LQSXW WR SXPS RHIILFLHQW GH SHUIRUPDQFH FRPSULV SDUW GH FRQVRPPDWLRQ GH OD SRPSH HL ZDVVHUGXUFKIOXVV LQ P K HDWLQJ ZDWHU IORZ UDWH LQ P K pELW G HDX GH FKDXIIDJH HQ P K HGLQJXQJHQ Â RQGLWLRQV Â RQGLWLRQV HL ZDVVHUGXUFKVDW HDWLQJ ZDWHU IORZ UDWH pELW G HDX GH FKDXIIDJH P K 9HUIO VVLJHU RQGHQVHU...

Page 15: ...PDWLRQ GH SXLVVDQFH FRPSULV SDUW GH FRQVRPPDWLRQ GH OD SRPSH UXFNYHUOXVW LQ 3D 3UHVVXUH ORVV LQ 3D 3HUWH GH SUHVVLRQ HQ 3D XIWHLQWULWWVWHPSHUDWXU LQ LU LQOHW WHPSHUDWXUH LQ 7HPSpUDWXUH G HQWUpH G DLU HQ XIWHLQWULWWVWHPSHUDWXU LQ LU LQOHW WHPSHUDWXUH LQ 7HPSpUDWXUH G HQWUpH G DLU HQ HLVWXQJV DKO LQFO 3XPSHQOHLVWXQJVDQWHLO RHIILFLHQW RI SHUIRUPDQFH LQFO SRZHU LQSXW WR SXPS RHIILFLHQW GH SHUIRUPDQFH ...

Page 16: ...A VI Anhang Appendix Annexes 3 3 Stromlaufpläne Circuit Diagrams Schémas électriques 3 1 Steuerung Standardregler Control of the standard controller Commande régulateur standard ...

Page 17: ... dimplex de A VII Anhang Appendix Annexes 3 2 3 2 Steuerung Kühlregler Control of the cooling controller Commande régulateur standard HJH 8PVFKDOWYHQWLO RXU ZD UHYHUVLQJ YDOYH 6RXSDSH GH FRPPXWDWLRQ YRLHV ...

Page 18: ...A VIII Anhang Appendix Annexes 3 3 3 3 Last Load Charge ...

Page 19: ...www dimplex de A IX Anhang Appendix Annexes 3 4 3 4 Anschlussplan Standardregler Terminal diagram for the standard controller Schéma électrique du régulateur standard ...

Page 20: ...endix Annexes 3 5 3 5 Anschlussplan Kühlregler Terminal diagram for the cooling controller Schéma électrique du régulateur refroidissement 7HPSHU 7HPS 7HPS HXFKWH XPLGLW XPLGLWp 7HPSHU 7HPS 7HPS HXFKWH XPLGLW XPLGLWp ...

Page 21: ...ilateur J13 J18 Relaisausgänge zur Ansteuerung der Systemkom ponenten 230 VAC Relay outputs for controlling system components 230 V AC Sorties de relais pour la commande des compo sants du système 230 V AC N2 J1 Stromversorgung N2 24VAC Power supply N2 24 V AC Alimentation en courant N2 24 V AC J2 J3 Sensoreingänge Sensor inputs Entrées de capteurs J4 Analogausgänge werden nicht genutzt Analogue o...

Page 22: ... terminal block Bornier distributeur charge réseau L N PE 230 V AC 50 Hz commande L N PE 230 V AC 50 Hz distributeur N et PE X2 1 Klemmenleiste Verteiler für 24VAC Terminal strip terminal block for 24 V AC Bornier distributeur distributeur pour 24 V AC X2 2 Klemmenleiste Verteiler für 0VAC Terminal strip terminal block for 0 V AC Bornier distributeur distributeur pour 0 V AC X2 3 Klemmenleiste Ver...

Page 23: ...www dimplex de A XIII Anhang Appendix Annexes 4 1 4 Hydraulisches Prinzipschema Hydraulic Plumbing Diagram Schéma hydraulique 4 1 Darstellung Schematic view Représentation ...

Page 24: ...cher Buffer tank Réservoir tampon Wärmepumpenregler Heat pump controller Régulateur de pompe à chaleur Elektroverteilung Electrical distribution system Distributeur courant électrique Warmwasserspeicher Hot water cylinder Ballon d eau chaude Kondensatablauf Condensate outflow Ecoulement des condensats Überdruck Heizwasser Overpressure of the heating water Surpression eau de chauffage E8 Zusatzheiz...

Page 25: ...www dimplex de A XV Anhang Appendix Annexes 5 5 Konformitätserklärung Declaration of Conformity Déclaration de conformité ...

Page 26: ...tschland GmbH Geschäftsbereich Dimplex Am Goldenen Feld 18 D 95326 Kulmbach Irrtümer und Änderungen vorbehalten Subject to alterations and errors Sous réserve d erreurs et modifications 49 0 9221 709 565 www dimplex de ...

Reviews: