www.dimplex.de 452162.66.04 · FD 9606
EN-19
English
LAW 6IMR - LAW 14ITR
13 Device information
1
Type and order code
LAW 6IMR
LAW 9IMR
LAW 14IMR
LAW 14ITR
2
Design
Heat source
Air
Air
Air
Air
2.1
Model
Split reversible
Split reversible
Split reversible
Split reversible
2.2
Controller
WPM Econ5Plus
integrated
WPM Econ5Plus
integrated
WPM Econ5Plus
integrated
WPM Econ5Plus
integrated
2.3
Thermal energy metering
No
No
No
No
2.4
Installation location
Indoors / outdoors
Indoors / outdoors
Indoors / outdoors
Indoors / outdoors
2.5
Performance level
Variable
Variable
Variable
Variable
3
Operating limits
3.1
Heating water flow / return
°C
up to 55 / from 20
up to 55 / from 20
up to 55 / from 20
up to 55 / from 20
3.2
Cooling water flow
°C
7 to 25
7 to 25
7 to 25
7 to 25
3.3
Air (heating)
°C
-20 to +30
-20 to +30
-20 to +30
-20 to +30
3.4
Air (cooling)
°C
+10 to +43
+10 to +43
+10 to +43
+10 to +43
4
Flow / sound
4.1
Heating water flow / internal pressure differential
in accordance with EN 14511
m³/h / Pa
1,6 / 20000
1,6 / 20000
2,4 / 30400
2,4 / 30400
free compression
Pa
38800
38800
29600
29600
Minimum heating water flow
internal pressure differential
m³/h
0,75 / 8500
0,75 / 8500
0,9 / 10000
0,9 / 10000
free compression
Pa
68500
68500
77300
77300
4.2
Noise-power level in accordance
with EN 12102 outdoors
1
dB(A)
63
63
68
67
4.3
Sound pressure level in 10 m distance outdoors
2
dB(A)
32
32
37
36
4.4
Noise-power level in accordance
with EN 12102 indoors
dB(A)
42
42
42
42
4.5
Sound pressure level in 1 m distance indoors
dB(A)
35
35
35
35
4.6
Air flow
m³/h / Pa
3600
3600
7200
7200
5
Dimensions, weight and filling quantities
5.1
Device dimensions
3
internal
H x W x D mm
external
H x W x D mm
1920 x 740 x 950
834 x 950 x 330
1920 x 740 x 950
834 x 950 x 330
1920 x 740 x 950
1380 x 950 x 330
1920 x 740 x 950
1380 x 950 x 330
5.2
Weight of the transportable unit(s)
incl. packaging internal / external
kg
215 / 69
215 / 69
222 / 94
222 / 116
5.3
Device connections for heating
inches
G 1 1/4"
G 1 1/4"
G 1 1/4"
G 1 1/4"
5.4
Refrigerant; total filling weight
type/kg
R410A / 1.9
R410A / 1.9
R410A / 2.38
R410A / 2.98
5.5
Lubricant; total filling quantity
type/litres
Polyvinyl ether
(PVE) / 0.9
Polyvinyl ether
(PVE) / 0.9
Polyvinyl ether
(PVE) / 1.3
Polyvinyl ether
(PVE) / 1.3
5.6
Volume of heating water in the outdoor component
Litres
0
0
0
0
5.7
Buffer tank
Nominal volume
in litres
100
100
100
100
Permissible operating temperature
°C
85
85
85
85
Max. operating overpressure
bar
3,0
3,0
3,0
3,0
Electrical pipe heater
kW
2, 4 or 6
2, 4 or 6
4
2, 4 or 6
2, 4 or 6
Immersion heater (optional)
kW
up to 6
up to 6
up to 6
up to 6
5.8
Domestic hot water cylinder
Usable capacity
in litres
277
277
277
277
Heat exchanger area
m²
3,15
3,15
3,15
3,15
Permissible operating temperature
°C
95
95
95
95
Max. operating pressure
bar
10,0
10,0
10,0
10,0
Immersion heater
kW
1,5
1,5
1,5
1,5
5.9
Start-to-leak pressure, safety valve
bar
2,5
2,5
2,5
2,5
6
Electrical connection
6.1
Supply voltage / fuse protection
Compressor
1~/N/PE 230 V
(50 Hz) / C25 A
1~/N/PE 230 V
(50 Hz) / C25 A
1~/N/PE 230 V
(50 Hz) / C40 A
Heating cartridge
1~/N/PE 230 V
(50 Hz) / C35 A
1~/N/PE 230 V
(50 Hz) / C35 A
1~/N/PE 230 V
(50 Hz) / C32 A
Comp
heating cartridge
3~/N/PE 400 V
(50 Hz) / C25 A
3~/N/PE 400 V
(50 Hz) / C25 A
3~/N/PE 400 V
(50 Hz) / C32 A
RCD-Type
B
B
B
B
Summary of Contents for LAW 14IMR
Page 2: ......
Page 64: ...FR 22 452162 66 04 FD 9606 www dimplex de Français LAW 6IMR LAW 14ITR ...
Page 90: ...A XXVI 452162 66 04 FD 9606 www dimplex de Anhang Appendix Annexes LAW 6IMR LAW 14ITR ...
Page 91: ...www dimplex de 452162 66 04 FD 9606 A XXVII Anhang Appendix Annexes LAW 6IMR LAW 14ITR ...