第3页/共6页
Dimplex inverter portable air conditioner trouble shooting and maintenance Guidance.
problem
cause
maintenance
tool
maintenance methods
important notes
Exhaust hose of lower
fan not able to produce
consistent air discharge
To check air discharge
from exhaust hose and to
replace it accordingly
◆驱动板芯片散热效果
不良
★
1.
检查驱动板固定芯片
之
M3
机械是否有滑牙现
象,如有请更换驱动板散
热器及
M3
机械螺丝。
★
2.
检查驱动板芯片上的
导热硅脂是否变干或不起
作用,如是请重新在芯片
涂上导热硅脂。
Driver chip not able to
release heat properly
1.To check driver chip
M3 wether has poor
connection.2.To check
driver chip silicon
grease,its status,it turn
out to be poor glueing
without any effect.then
please to glue it again
◆
HEAT
压缩机过载保护
配线端子松
★拆机,目测各主板
CN5
配线端子是否有松脱现
象,如有请重新插好。
heat compressor
overprotection with poor
wiring connection
discharge the unit, to test
CN5 wiring terminal
connection whether is
ok.or otherwise to re-
connect again
qualified technician to
ensure the live parts to
be earthly grounded in
order to protect the parts
to be safely operated
四、打水马达不
转
Water motor is
out of working
◆打水马达配线松脱
◆打水飞轮卡死
◆打水马达损坏
十字螺丝刀
★
1.
拆机,检查打水马达
配线端子是否有脱落现
象,如是请重新插好。
★
2.
检查打水飞轮是否与
冷凝器铝翅片卡死现象,
如是请把翅片调整避开打
水飞轮。
★
3.
更换打水马达
※拆机前机台需有半分
钟以上的放电时间
,
以免
电击伤人。
water motor with poor
wiring connection
water motor unworkable
water motor damaged
To use screw
driver
Discharge the unit, to
test CN5 wiring terminal
connection whether is
ok.or otherwise to re-
connect again
please wait at least 30
seconds before
discharging the units,
This is to ensure not
harming users
十字螺丝刀
三、压缩机运行
一段时间反复跳
停
Compressor
frequently off
working after
runing a while
※维修人员需接上可靠
的接地,以免静电损坏
主板元件
Summary of Contents for GDC16RWA
Page 1: ...变频空调检修外观拆卸指引 ...