Dimplex inverter portable air conditioner trouble shooting and maintenance Guidance.

problem

cause

maintenance

tool

maintenance methods

important notes

◆电源线插头与插座接
触不良

★更换接触良好的插座

Incompatiblity
happened at connection
of power plug & its
power socket

Replace with workable
power plug accordingly

◆滤波器烧坏

★机器上电开机

,

使用万用

表在滤波器

OUT

端测试棕

/

蓝端子电压是否有

AC220-240V

电压输出

?

有烧坏主更换之。

wave filter being
damaged

turn on the unit.to use
multimeter to detect
wave filter "out- signal" to
verfify the voltage wether
at 220-240V.or otherwise
to replace it

◆主板

20A

保险丝烧坏

★目测主板保险丝是否烧

,

如有烧断即更换之。

mainboard fuse of input
current 20A was
damaged

To detect the fuse wether
workable or not
otherwise to replace it

CN52

CN57

配线端

子松脱

★目测主板

CN52\57

是否

松脱

,

如是请用钳子把端子

夹紧重插。

CN52 or CN57 with
loose wiring connection

To detect the wiring
connection and affirm It
by using pincer

◆主板烧坏

★目测主板电子元件是否
有明显熏黑、漏电短路爆
裂现象,如是请更换主板

mainboard damaged

To check any sportmarks
on mainboard chips & its
workability not having
short circuit otherwise to
replace the new one

◆压缩机过热保护未解

★用温度计测试排气管湿
度是否高于

125

℃,如是

证明其热保护开启,待冷
却后再上电运行。

overheat protection of
compressor fail to
funtion

thermometer to check
tempreture at 125

,If

detect to be overheat but
only to plug on after it is
cool down

5P

通信配线端子松

★目测主板

CN801

插座

&

驱动板

CN7

插座配线端是

否松脱,如是请重新插好
再上电。

万用表

  

十字螺丝

刀 尖嘴钳

一、上电无反应

No signaling-
Electrical live
parts

1.

断电后半分钟以上,

方可拆机检查。以免电
击伤人和烧毁万用表。

2.

维修人员需接上可靠

的接地,以免静电损坏
主板元件。

3.

主板更换时,请先记

录各配线配插位置,再
实施拆卸,以免安装新
板时配错线上电损坏主
板。

     1.please wait at

leat 30 seconds before
discharging unit for
checking.This is to
ensure not harming user
& multimeter.
2.qualified technician to
ensure the live parts to
be earthly grounded in
order to protect the parts
to be safely operated
3.Please record all the
socket lot and wiring
connection before
replacing the new
mainboard.This is to
ensure correct wiring
connection to protect the
live parts

1.

断电后半分钟以上,

方可拆机检查。以免电
击伤人和烧毁万用表

2.

维修人员需接上可靠

的接地,以免静电损坏

Summary of Contents for GDC16RWA

Page 1: ...变频空调检修外观拆卸指引 ...

Page 2: ... 有明显熏黑 漏电短路爆 裂现象 如是请更换主板 mainboard damaged To check any sportmarks on mainboard chips its workability not having short circuit otherwise to replace the new one 压缩机过热保护未解 除 用温度计测试排气管湿 度是否高于125 如是 证明其热保护开启 待冷 却后再上电运行 overheat protection of compressor fail to funtion thermometer to check tempreture at 125 If detect to be overheat but only to plug on after it is cool down 5P通信配线端子松 目测主板CN801插座 驱动板CN7插...

Page 3: ...citor with any spot marks or signs of damages To use multimeter to check battery volumne otherwise to replace new ones 压缩机启动不工作 上电启动机器 用手触摸 压缩机机体 压缩机有启 动 但不工作 机体不发 热 如是请送修更换 Compressor out of working Turn on unit and compressor is on but fail to operate no heat Please send it to replace 下风机排气风管排气 不顺畅 检查下风机排气风管管 路是否顺畅 如否请清理之 让其顺畅 二 压缩机不启 动 启动不工作 Compressor not working 温度计 万 用表 十字螺 丝刀 尖嘴钳 主板元件 3 遇到如...

Page 4: ...请重新插好 heat compressor overprotection with poor wiring connection discharge the unit to test CN5 wiring terminal connection whether is ok or otherwise to re connect again qualified technician to ensure the live parts to be earthly grounded in order to protect the parts to be safely operated 四 打水马达不 转 Water motor is out of working 打水马达配线松脱 打水飞轮卡死 打水马达损坏 十字螺丝刀 1 拆机 检查打水马达 配线端子是否有脱落现 象 如是请重新插好 2 检查打水飞...

Page 5: ... repair service center 六 显示E1 室内温度传感器故障 to use screw driver 1 拆机 目测检查室内 温度传感器的插头是否牢 靠的插于主板CN10端子 座上 如否请重新插好固 定牢固 2 如重新插好仍显示 E1 此时需更换室内温度 传感器了 维修人员需接上可靠 的接地 以免静电损坏 主板元件 Display E1 room tempreture sensor errors 1 Discharge the unit to check the tempreture sensor integrate into CN10 wiring terminal 2 If display E1 after re plug please to change the tempreture sensor qualified technicians to ensure th...

Page 6: ... To check pin 3 pin 5 signal transmitting wether connect properly or not 主板IC松 接触不良 十字螺丝刀 摄子 拆机 目测检查主板模 块是否牢靠的插于主板 IC1的IC座上 如有松动 请重新插好 mainboard IC loose due to connecting problems use screw driver pincer discharge the unit To check mainboard connetion of IC1 IC socket firmly fixing or not 十 显示E5 EEPROM 故障 十字螺丝刀 摄子 拆机 更换主板IC14 E5 display EEPROM signal errors use screw driver pincer discharge the u...

Page 7: ...maintenance methods important notes E7 display water full signal water motor fault use screw driver 1 discharge the water plug and drain water and then plug on the unit 2 discharge the unit to check micro switch wiring wether firmly fix to CN9 socket 3 If detect is belong to water motor fault then to replace the water motor ...

Page 8: ...piece pic 3 Discharge the right back panel 2 1 Discharge the screws as shown on pic 3 2 2 Pull down the right back panel piece pic 4 Dimplex PCI变频空调检修外观拆卸指引 Side casing discharge 3 1 Discharge the screws as shown on pic 4 3 2 Pull down the left right back panel piece see pic 5 6 1 1使用十字批头 将 图1 红色圈圈 的螺丝拆卸 1 2使用六角梅花批头 将 图2 的安 全螺丝拆卸 1 3取下左上后背板 如 图3 2 1使用十字批头 将 图3 红 色圈圈的螺丝拆卸 2 2取下右上后背板 后背板 下 如 图4 3 1使...

Page 9: ...第2页 共2页 Front casing discharge 4 1 Discharge the screws as shown on pic 5 6 7 4 2 Pull down the panel piece see pic 8 9 4 1使用十字批头 将 图5 6 7 红 色圈圈的螺丝拆卸 4 2取下外壳 如 图8 9 ...

Page 10: ...打水飞轮 water motor wheel 室外排气传感器 Air discharge tempreture sensor 室内温度传感器 room tempreture sensor 室内盘管传感器 evaporator tempreture sensor 蒸发器 evaporator 2200uF电解电容 2200UF capacitor 下马达12uF电容 lower motor with 12uf capacitor 上马达8uF电容 upper motor with 8uf 水满微动开关 water full micro 滤波器 wave filter 电抗 Resistor 下马达 lower motor 上马达 upper motor 零件名称 压缩机 compressor 主板 mainboard 驱动板 driver ...

Page 11: ...er full switch wiring socket 29 mainbord evaporator tempreture sensor socket 30 mainbord overload protector of compressor 31 mainbord CN52 wiring terminal 32 mainbord CN57 wiring terminal 33 driver 5p transimission socket 34 driver 3p transimission socket 35 silicon grease driver chip slot 36 overload protector of compressor 驱动板5P通信配线座 驱动板3P通信配线座 导热硅脂 驱动板芯片 压缩机过载保护器 零件名称 主板IC1 主板IC14 主板20A保险丝 主板5P...